Parameter values of process data preconfiguration, Feldbus-baugruppe 2113 interbus, 1 pi-data – Lenze EMF2113IB User Manual
Page 113: Show/hide bookmarks

Appendix
Parameter values of process data preconfiguration
7
Feldbus-Baugruppe 2113 INTERBUS
7.8
7.8.2
L
7.8-4
EDSIBS-1.0-06/2003
According to the standardization of controller parameters according to the
DRIVECOM profile 21 the following parameters are implemented:
Index
hex
Index
dec
Parameter name
R/W
PD
SP Data
str.
Data
type
Data
number
Data
length
6000
24576
Process-input data description
Ra/W
-
Y
R
PDS
≤ 41
≤ 61
6001
24577
Process-output data description
Ra/W
-
Y
R
PDS
≤ 41
≤ 61
6002
24578
Process-output data - release
Ra/W
-
n
S
OS
4
4
6003
24579
Process data monitoring time
Ra/W
-
Y
S
U16
1
2
6004
24580
Process-data - selection code
Ra/W
-
Y
S
I16
1
2
603F
24639
Error code
Ra
-
n
S
OS
1
2
6040
24640
Control word
Ra/W
POI
-
S
OS
2
2
6041
24641
Status word
Ra
PE
-
S
OS
2
2
6042
24642
Speed setpoint
Ra/W
POI
-
S
I16
1
2
6043
24643
Master speed
Ra
-
-
S
I16
1
2
6044
24644
Actual speed
Ra
PE
-
S
I16
1
2
6046
24646
Speed - min./max. value
Ra/W
-
n
A
U32
2
8
6048
24648
Acceleration
Ra/W
-
n
R
RS
2
6
6049
24649
Deceleration
Ra/W
-
n
R
RS
2
6
604A
24650
Quick stop
Ra/W
-
n
R
RS
2
6
604B
24651
Setpoint factor
Ra/W
-
Y
A
I16
2
4
604D
24653
Pole number
Ra/W
-
Y
S
U8
1
1
604E
24654
Speed reference value
Ra/W
-
n
S
U32
1
4
604F
24655
Acceleration time
Ra/W
-
n
S
U32
1
4
6050
24656
Deceleration
Ra/W
-
n
S
U32
1
4
6051
24657
Quick stop time
(not with 820X)
Ra/W
-
n
S
U32
1
4
6052
24658
Percentage setpoint
Ra/W
POI
-
S
I16
1
2
6053
24659
Master percentage
Ra
-
-
S
I16
1
2
6054
24660
Actual percentage
Ra
PE
-
S
I16
1
2
7.8.2
Parameter values of process data preconfiguration
7.8.2.1
PI-data
L-C0009 L-C1910
*)
L-C1911
*)
Index 6000, subindex:
2 / 3
6 / 7
10 / 11
14 / 15
18 / 19
22 / 23
26 / 27
30 / 31
34 / 35
38 / 39
11
0
5F69 / 0
5CA5 / 1
12
0
5CA5 / 1
5CA5 / 2
13
0
5CA5 / 2
5CA5 / 3
14
40000
10000
6041 / 0
6044 / 0
15
40000
10000
6041 / 0
6054 / 0
16
10000
6041 / 0
5CA5 / 1
17
0
5F69 / 0
6044 / 0
18
0
5F69 / 0
6054 / 0
21
10000
6041 / 0
6044 / 0
5CA5 / 2
5CA5 / 3
5CA5 / 4
5CA5 / 5
5CA5 / 6
5CA5 / 7
5CA5 / 8
5CA5 / 9
22
10000
6041 / 0
6054 / 0
5CA5 / 2
5CA5 / 3
5CA5 / 4
5CA5 / 5
5CA5 / 6
5CA5 / 7
5CA5 / 8
5CA5 / 9
23
60000
10000
6041 / 0
5CA5 / 1
5CA5 / 2
5CA5 / 3
5CA5 / 4
5CA5 / 5
5CA5 / 6
5CA5 / 7
5CA5 / 8
5CA5 / 9
24
60000
10000
6041 / 0
5CA5 / 2
5CA5 / 3
5CA5 / 4
5CA5 / 5
5CA5 / 6
5CA5 / 7
5CA5 / 8
5CA5 / 9
5CA5 / 10
25
0
5F69 / 0
5CA5 / 1
5CA5 / 2
5CA5 / 3
5CA5 / 4
5CA5 / 5
5CA5 / 6
5CA5 / 7
5CA5 / 8
5CA5 / 9
26
0
5F69 / 0
5CA5 / 2
5CA5 / 3
5CA5 / 4
5CA5 / 5
5CA5 / 6
5CA5 / 7
5CA5 / 8
5CA5 / 9
5CA5 / 10
27
60000
0
5CA5 / 1
5CA5 / 2
5CA5 / 3
5CA5 / 4
5CA5 / 5
5CA5 / 6
5CA5 / 7
5CA5 / 8
5CA5 / 9
5CA5 / 10
*)
This entry is only effective if switches S1 ... S7 = OFF.
Show/Hide Bookmarks