Feldbus-baugruppe 2113 interbus, Appendix code table – Lenze EMF2113IB User Manual
Page 111

Appendix
Code table
7
Feldbus-Baugruppe 2113 INTERBUS
7.8
7.8.1
L
7.8-2
EDSIBS-1.0-06/2003
7.8.1.2
Controller codes
Code
Values
Lenze
setting
Explanation
L-C0001
Operating mode
0
1
2
3
Control source
Terminal
Terminal
Terminal
INTERBUS
Setpoint source
Terminal
8201BB
Terminal
INTERBUS
Parameter source
INTERBUS
INTERBUS (operating
module)
INTERBUS
INTERBUS
L-C0009
Process data preconfiguration
)
Please see the notes in chapter 7.8.2
L-C0142
This parameter L-C0142 prevents the drive from uncontrolled restarts
after:
•
Mains switching
•
Internal fault
•
Internal message (with pulse inhibit) > 0.5 s
If the controller sets the status ”message” because of a failure (e.g. short
mains failure) and the fault remains active for longer than 0.5 s, controller
inhibit will be set automatically.
The parameter L-C0142 has the following function:
•
L-C0142 = 1:
The drives will restart automatically as soon as the error has been
eliminated.
•
L-C0142 = 0:
The controller remains inhibited and the drive cannot restart even if
the error has been eliminated.
– The drive restarts after a LOW-HIGH transition at one of the inputs
for ”controller inhibit” (CINH, e.g. at terminal X5/28) wieder an
All codes are described in detail in the corresponding Operating Instructions.
Show/Hide Bookmarks