beautypg.com

Weil mclain, Series boiler – Beckett BRYAN STEAM CF2500A User Manual

Page 32

background image

Weil McLain

80

Series Boiler

Boiler

Burner

Chassis

Spec.

Air Tube

Combination

High

Fire
Rate

Nozzle

Head

Setting

Blue -

Low Fire

Air or

Shutter

Red -

High Fire

Air or

Band

Low Fire

Pump

Press.

High Fire

Pump

Press.

Pressure

Firing
Flange

Insertion

380

CF500

BCF809

CF60KK

2.40

2.00x60B (D) 1-1/2

4

0

N/A

140

51311

3.00"

480

CF500

BCF809

CF60KK

3.40

2.75x45PLP

4

10

3

N/A

150

51311

3.00"

580

CF800

BCF403

CF60KHS

4.45

3.75x30P

2

7

0

N/A

150

51311

3.00"

680

CF800

BCF403

CF60KHS

5.50

4.50x45P

4

10

3

N/A

150

51311

3.00"

780

CF1400

BCF205

CF66KD

6.50

3.75x45P

3

20

45

150

300

51629

4.00"

880

CF1400

BCF205

CF66KD

7.50

4.50x45P

4

25

45

150

275

51629

4.00"

980

CF1400

BCF205

CF66KD

8.50

5.00x45P

5

25

60

150

300

51629

4.00"

1080

CF1400

BCF205

CF66KE

9.60

5.50x45P

3

30

60

150

300

51629

4.00"

1180

CF2300A

BCF304

CF66KG

10.60

6.00x45P

0

15

30

150

300

51630

4.00"

1280

CF2300A

BCF304

CF66KG

11.60

7.00x45P

1/2

30

60

150

280

51630

4.00"

Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.