Bryant Deluxe 4 WAy Gas Furnase 355MAV User Manual
Page 52

NOTE: DO NOT set low-heat manifold pressure less than 1.3-in. wc or more than 1.7-in. wc for natural gas. If manifold pressure is outside this
range, change main burner orifices.
CAUTION: DO NOT bottom out gas valve regulator adjusting screw. This can result in unregulated manifold pressure
and result in excess overfire and heat exchanger failures.
NOTE: If orifice hole appears damaged or it is suspected to have been redrilled, check orifice hole with a numbered drill bit of correct size. Never
redrill an orifice. A burr-free and squarely aligned orifice hole is essential for proper flame characteristics.
f. Move setup switch SW-2 to OFF position after completing low-heat adjustment.
g. Jumper R and W2 thermostat connections on control center. (See Fig. 31.) This keeps furnace locked in high-heat operation.
h. Turn high-heat adjusting screw (5/64 hex Allen wrench) counterclockwise (out) to decrease input rate or clockwise (in) to increase rate.
NOTE: DO NOT set high-heat manifold pressure less than 3.2-in. wc or more than 3.8-in. wc for natural gas. If manifold pressure is outside this
range, change main burner orifices.
i. When correct input is obtained, replace caps that conceal gas valve regulator adjustment screws. Main burner flame should be clear blue,
almost transparent. (See Fig. 58.)
Table 13—Model 355MAV Orifice Size and Manifold Pressure for Correct Input
(Tabulated Data Based on 20,000 Btuh High Heat/13,000 Btuh Low Heat per Burner, Derated 2 Percent for Each 1000 ft Above
Sea Level)
ALTITUDE
RANGE
(FT)
AVG GAS
HEAT VALUE
(BTU/CU FT)
SPECIFIC GRAVITY OF NATURAL GAS
0.58
0.60
0.62
0.64
0.66
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
U.S.A.
and
Canada
0
to
2000
850
43
3.7/1.5
43
3.8/1.6
42
3.2/1.4
42
3.3/1.4
42
3.4/1.4
875
43
3.5/1.5
43
3.6/1.5
43
3.7/1.6
43
3.8/1.6
42
3.2/1.4
900
44
3.7/1.6
43
3.4/1.4
43
3.5/1.5
43
3.6/1.5
43
3.7/1.6
925
44
3.5/1.5
44
3.7/1.6
44
3.8/1.6
43
3.4/1.4
43
3.5/1.5
950
44
3.4/1.4
44
3.5/1.5
44
3.6/1.5
44
3.7/1.6
44
3.8/1.6
975
44
3.2/1.3
44
3.3/1.4
44
3.4/1.4
44
3.5/1.5
44
3.6/1.5
1000
45
3.7/1.6
45
3.8/1.6
44
3.2/1.4
44
3.4/1.4
44
3.5/1.5
1025
45
3.5/1.5
45
3.6/1.5
45
3.7/1.6
44
3.2/1.3
44
3.3/1.4
1050
45
3.3/1.4
45
3.4/1.5
45
3.6/1.5
45
3.7/1.6
45
3.8/1.6
1075
45
3.2/1.3
45
3.3/1.4
45
3.4/1.4
45
3.5/1.5
45
3.6/1.5
1100
47
3.6/1.5
47
3.7/1.6
45
3.2/1.4
45
3.4/1.4
45
3.5/1.5
ALTITUDE
RANGE
(FT)
AVG GAS
HEAT VALUE
(BTU/CU FT)
SPECIFIC GRAVITY OF NATURAL GAS
0.58
0.60
0.62
0.64
0.66
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
U.S.A.
and
Canada
Altitudes
2001
to
3000
or
Canada
Altitudes
2000
to
4500
775
43
3.8/1.6
42
3.2/1.4
42
3.3/1.4
42
3.4/1.4
42
3.5/1.5
800
43
3.5/1.5
43
3.7/1.5
43
3.8/1.6
42
3.2/1.4
42
3.3/1.4
825
44
3.8/1.6
43
3.4/1.5
43
3.6/1.5
43
3.7/1.5
43
3.8/1.6
850
44
3.6/1.5
44
3.7/1.6
44
3.8/1.6
43
3.5/1.5
43
3.6/1.5
875
44
3.4/1.4
44
3.5/1.5
44
3.6/1.5
44
3.7/1.6
43
3.4/1.4
900
44
3.2/1.4
44
3.3/1.4
44
3.4/1.4
44
3.5/1.5
44
3.6/1.5
925
45
3.7/1.5
45
3.8/1.6
44
3.2/1.4
44
3.3/1.4
44
3.4/1.5
950
45
3.5/1.5
45
3.6/1.5
45
3.7/1.6
45
3.8/1.6
44
3.3/1.4
975
45
3.3/1.4
45
3.4/1.4
45
3.5/1.5
45
3.6/1.5
45
3.8/1.6
1000
47
3.7/1.6
45
3.2/1.4
45
3.4/1.4
45
3.5/1.5
45
3.6/1.5
1025
47
3.6/1.5
47
3.7/1.6
45
3.2/1.3
45
3.3/1.4
45
3.4/1.4
ALTITUDE
RANGE
(FT)
AVG GAS
HEAT VALUE
(BTU/CU FT)
SPECIFIC GRAVITY OF NATURAL GAS
0.58
0.60
0.62
0.64
0.66
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
Orifice
no.
Manifold
Pressure
U.S.A.
Only
3001
to
4000
750
43
3.7/1.6
43
3.8/1.6
42
3.3/1.4
42
3.4/1.4
42
3.5/1.5
775
43
3.5/1.5
43
3.6/1.5
43
3.7/1.6
43
3.8/1.6
42
3.2/1.4
800
44
3.7/1.6
43
3.4/1.4
43
3.5/1.5
43
3.6/1.5
43
3.7/1.6
825
44
3.5/1.5
44
3.6/1.5
44
3.8/1.6
43
3.4/1.4
43
3.5/1.5
850
44
3.3/1.4
44
3.4/1.4
44
3.5/1.5
44
3.7/1.5
44
3.8/1.6
875
45
3.8/1.6
44
3.2/1.4
44
3.3/1.4
44
3.5/1.5
44
3.6/1.5
900
45
3.6/1.5
45
3.7/1.6
45
3.8/1.6
44
3.3/1.4
44
3.4/1.4
925
45
3.4/1.4
45
3.5/1.5
45
3.6/1.5
45
3.7/1.6
44
3.2/1.3
950
45
3.2/1.4
45
3.3/1.4
45
3.4/1.5
45
3.5/1.5
45
3.7/1.5
975
47
3.6/1.5
45
3.2/1.3
45
3.3/1.4
45
3.4/1.4
45
3.5/1.5
1000
47
3.5/1.5
47
3.6/1.5
45
3.7/1.6
45
3.2/1.4
45
3.3/1.4
* Orifice numbers 45 are factory installed.
—52—