NOTE: DO NOT set low-heat manifold pressure less than 1.3-in. wc or more than 1.7-in. wc for natural gas. If manifold pressure is outside this

range, change main burner orifices.

CAUTION: DO NOT bottom out gas valve regulator adjusting screw. This can result in unregulated manifold pressure

and result in excess overfire and heat exchanger failures.

NOTE: If orifice hole appears damaged or it is suspected to have been redrilled, check orifice hole with a numbered drill bit of correct size. Never

redrill an orifice. A burr-free and squarely aligned orifice hole is essential for proper flame characteristics.

f. Move setup switch SW-2 to OFF position after completing low-heat adjustment.
g. Jumper R and W2 thermostat connections on control center. (See Fig. 31.) This keeps furnace locked in high-heat operation.
h. Turn high-heat adjusting screw (5/64 hex Allen wrench) counterclockwise (out) to decrease input rate or clockwise (in) to increase rate.

NOTE: DO NOT set high-heat manifold pressure less than 3.2-in. wc or more than 3.8-in. wc for natural gas. If manifold pressure is outside this

range, change main burner orifices.

i. When correct input is obtained, replace caps that conceal gas valve regulator adjustment screws. Main burner flame should be clear blue,

almost transparent. (See Fig. 58.)

Table 13—Model 355MAV Orifice Size and Manifold Pressure for Correct Input

(Tabulated Data Based on 20,000 Btuh High Heat/13,000 Btuh Low Heat per Burner, Derated 2 Percent for Each 1000 ft Above

Sea Level)

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

no.

Manifold

Pressure

Orifice

no.

Manifold

Pressure

Orifice

no.

Manifold

Pressure

Orifice

no.

Manifold

Pressure

Orifice

no.

Manifold

Pressure

U.S.A.

and

Canada

0

to

2000

850

43

3.7/1.5

43

3.8/1.6

42

3.2/1.4

42

3.3/1.4

42

3.4/1.4

875

43

3.5/1.5

43

3.6/1.5

43

3.7/1.6

43

3.8/1.6

42

3.2/1.4

900

44

3.7/1.6

43

3.4/1.4

43

3.5/1.5

43

3.6/1.5

43

3.7/1.6

925

44

3.5/1.5

44

3.7/1.6

44

3.8/1.6

43

3.4/1.4

43

3.5/1.5

950

44

3.4/1.4

44

3.5/1.5

44

3.6/1.5

44

3.7/1.6

44

3.8/1.6

975

44

3.2/1.3

44

3.3/1.4

44

3.4/1.4

44

3.5/1.5

44

3.6/1.5

1000

45

3.7/1.6

45

3.8/1.6

44

3.2/1.4

44

3.4/1.4

44

3.5/1.5

1025

45

3.5/1.5

45

3.6/1.5

45

3.7/1.6

44

3.2/1.3

44

3.3/1.4

1050

45

3.3/1.4

45

3.4/1.5

45

3.6/1.5

45

3.7/1.6

45

3.8/1.6

1075

45

3.2/1.3

45

3.3/1.4

45

3.4/1.4

45

3.5/1.5

45

3.6/1.5

1100

47

3.6/1.5

47

3.7/1.6

45

3.2/1.4

45

3.4/1.4

45

3.5/1.5

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

no.

Manifold

Pressure

Orifice

no.

Manifold

Pressure

Orifice

no.

Manifold

Pressure

Orifice

no.

Manifold

Pressure

Orifice

no.

Manifold

Pressure

U.S.A.

and

Canada

Altitudes

2001

to

3000

or

Canada

Altitudes

2000

to

4500

775

43

3.8/1.6

42

3.2/1.4

42

3.3/1.4

42

3.4/1.4

42

3.5/1.5

800

43

3.5/1.5

43

3.7/1.5

43

3.8/1.6

42

3.2/1.4

42

3.3/1.4

825

44

3.8/1.6

43

3.4/1.5

43

3.6/1.5

43

3.7/1.5

43

3.8/1.6

850

44

3.6/1.5

44

3.7/1.6

44

3.8/1.6

43

3.5/1.5

43

3.6/1.5

875

44

3.4/1.4

44

3.5/1.5

44

3.6/1.5

44

3.7/1.6

43

3.4/1.4

900

44

3.2/1.4

44

3.3/1.4

44

3.4/1.4

44

3.5/1.5

44

3.6/1.5

925

45

3.7/1.5

45

3.8/1.6

44

3.2/1.4

44

3.3/1.4

44

3.4/1.5

950

45

3.5/1.5

45

3.6/1.5

45

3.7/1.6

45

3.8/1.6

44

3.3/1.4

975

45

3.3/1.4

45

3.4/1.4

45

3.5/1.5

45

3.6/1.5

45

3.8/1.6

1000

47

3.7/1.6

45

3.2/1.4

45

3.4/1.4

45

3.5/1.5

45

3.6/1.5

1025

47

3.6/1.5

47

3.7/1.6

45

3.2/1.3

45

3.3/1.4

45

3.4/1.4

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

no.

Manifold

Pressure

Orifice

no.

Manifold

Pressure

Orifice

no.

Manifold

Pressure

Orifice

no.

Manifold

Pressure

Orifice

no.

Manifold

Pressure

U.S.A.

Only

3001

to

4000

750

43

3.7/1.6

43

3.8/1.6

42

3.3/1.4

42

3.4/1.4

42

3.5/1.5

775

43

3.5/1.5

43

3.6/1.5

43

3.7/1.6

43

3.8/1.6

42

3.2/1.4

800

44

3.7/1.6

43

3.4/1.4

43

3.5/1.5

43

3.6/1.5

43

3.7/1.6

825

44

3.5/1.5

44

3.6/1.5

44

3.8/1.6

43

3.4/1.4

43

3.5/1.5

850

44

3.3/1.4

44

3.4/1.4

44

3.5/1.5

44

3.7/1.5

44

3.8/1.6

875

45

3.8/1.6

44

3.2/1.4

44

3.3/1.4

44

3.5/1.5

44

3.6/1.5

900

45

3.6/1.5

45

3.7/1.6

45

3.8/1.6

44

3.3/1.4

44

3.4/1.4

925

45

3.4/1.4

45

3.5/1.5

45

3.6/1.5

45

3.7/1.6

44

3.2/1.3

950

45

3.2/1.4

45

3.3/1.4

45

3.4/1.5

45

3.5/1.5

45

3.7/1.5

975

47

3.6/1.5

45

3.2/1.3

45

3.3/1.4

45

3.4/1.4

45

3.5/1.5

1000

47

3.5/1.5

47

3.6/1.5

45

3.7/1.6

45

3.2/1.4

45

3.3/1.4

* Orifice numbers 45 are factory installed.