beautypg.com

Enerpac CDT-Series User Manual

Page 7

background image

7

CAUTION: Do not exceed oil
temperatures above 150 °F [65 °C].

Use clean, high-quality, hydraulic oil in your
system. Use of Enerpac hydraulic oil, part
number HF series is highly recommended.

Contaminated oil causes premature wear
to moving parts and seals. Frequency
of changing oil depends on operating
conditions and filters within your system,
but you should follow a regular maintenance
schedule. Dispose of used oil properly.
Enerpac offers ready-to-use spare parts kits
for repair and/or replacements. Repair parts
sheets containing parts drawings and parts
lists are available. Contact Enerpac.

Illustration 4 – Manifold for CSM cylinders

Illustration 5 – Manifold for CSM cylinders

Table C5 Manifold dimensions in inches (see illustration 5)

Model

B C

D

min

E

SAE

Torque

O-ring

No.

A

max

Full

min

Nm

(DI X W)

min

Thread

[ft-lbs]

CSM 271

.97

9

/

16

"-18 UNF

.097

.50

1.02

#6

30 [21]

.47 x. 078

CSM2131

1.43

CSM571

1.34

7

/

8

"-14 UNF

.100

.66

1.14

#10

98 [72]

.76 x .097

CSM5131

1.50

CSM1071

1.14

CSM0131 1.63

1

1

/

16

"-12 UNF

.130

.75

1.38

#12 150 [108] .92 x .116

CSM10191

1.97

CSM18131

1.91 1

5

/

16

"-12 UN

.130

.75

1.54

#16 250 [188] 1.17 x .116

CSM18251

2.28

CSM27151

2.27 1

5

/

8

"-12 UN

.132

.75

1.54

#20 400 [295] 1.48 x .118

CSM27251

2.32

This manual is related to the following products: