0 installation – Enerpac CDT-Series User Manual
Page 5

Table A, Dimensions in mm
Model No.
Body Thread
Plunger ID Thread
Hyd Port
CST272
CST2102
M12
x
1,5
–
G
1
⁄
8
"
CST2132
CST572
CST5132
CST5192
M20
x
1,5
M4
G
1
⁄
8
"
CST5252
CST5382
CST1072
CST10132
CST10192
M28
x
1,5
M6
G
1
⁄
4
"
CST10252
CST10382
CDT18132
CDT18252
M48
x
1,5
M10
G
1
⁄
4
"
CDT18502
CDT27152
CDT27252
M55
x
1,5
M8
G
1
⁄
4
"
CDT27502
CDT40132
CDT40252
M48 x 1,5
M10
G
1
⁄
4
"
CDT4038
CDT40502
5.0 INSTALLATION
IMPORTANT: It is mandatory that the 
operator has a full understanding of all 
instructions, safety regulations, cautions and 
warnings, before starting to operate any of 
the equipment. In case of doubt contact 
Enerpac.
WARNING: To avoid personal injury
and possible equipment damage make
sure the manifold or fixture, all fittings and 
piping are able to withstand the operating 
pressure of 5000 psi [350 bar] (35 MPa).
WARNING: Use hydraulic gauges to
indicate safe operating pressures in
each hydraulic system. Do not exceed the 
safety limits of the lowest rated component 
within your hydraulic system.
Mount the cylinder in your hydraulic system. 
In the CST models there is only one oil 
port in the bottom of the cylinder. In the 
CDT models the oil ports are marked: port 
A - plunger extended; port B - plunger 
retracted (see Illustration 2).
5