beautypg.com

Det-Tronics U9500 Infiniti Gas Transmitter User Manual

Page 4

background image

95-8444

2

10.1

DETECTION RANGE—

Hydrocarbon:

0 to 100% LFL for PointWatch IR

detector. (FM/CSA verified)

Catalytic:

0 to 100% LFL.

Hydrogen Sulfide 0 to 100 ppm, 0 to 50 ppm, 0 to 20 ppm

(electrochemical) (FM/CSA verified)

Chlorine:

0 to 10 ppm.

Oxygen:

0 to 25% by volume.

Carbon Monoxide: 0 to 100 ppm, 0 to 500 ppm, 0 to

1000 ppm.

Sulfur Dioxide:

0 to 100 ppm.

RELAY CONTACTS (OPTIONAL)—

Three Alarm relays: Form C, 5 amperes at 30 Vdc.

Selectable normally energized or de-energized as a

group. Low, auxiliary and high alarm relay contacts are

selectable as a group for latching or non-latching.

Warning

When in non-latching mode, the control device
must latch the alarm output.

One Fault relay: Form C, 5 amperes at 30 Vdc. Normally

energized for no fault condition with power applied to

device.

TEMPERATURE RANGE—

Operating:

–40°F to +167°F (–40°C to +75°C).

Storage:

–67°F to +185°F (–55°C to +85°C).

WIRING—

Power: 18 AWG (0.75 mm

2

) minimum is recommended

for power wiring to the transmitter. Larger diameter wire

may be required to maintain a minimum of 16 Vdc at the

transmitter for all operating conditions for all sensors

except PointWatch. A minimum of 18 Vdc is required

at the transmitter for all operating conditions for the

PointWatch sensor. Maximum wire size for terminals is

12 AWG (4 mm

2

).

SHIPPING WEIGHT

(Transmitter and Junction Box)—

Aluminum:

4.15 pounds (1.88 kilograms)

Stainless steel: 10.5 pounds (4.76 kilograms).

ENCLOSURE MATERIAL—

Epoxy coated 356 alloy aluminum or 316 stainless steel.

DIMENSIONS—

See Figure 1.

CERTIFICATION—

For complete approval details, refer to the appropriate

Appendix:

Appendix A - FM

Appendix B - CSA

Appendix C - ATEX/CE

Appendix D - IECEx

Appendix E - Additional approvals.

Table 1—Power Consumption with Sensor

Type

Infiniti with alarm relays

(sensor connected, 24 Vdc+ input)

Infiniti without alarm relays

(sensor connected, 24 Vdc+ input)

Nominal

Maximum

Nominal

Maximum

Toxic and Oxygen

3 Watts

5 Watts

2.1 Watts

2.4 Watts

Combustible

4.6 Watts

6.5 Watts

3.5 Watts

4 Watts

PointWatch

TM

PIR9400

8.1 Watts

10.0 Watts

7.0 Watts

7.5 Watts

PointWatch Eclipse

®

PIRECL

7.6 Watts

12.4 Watts

6.5 Watts

9.9 Watts

NOTE: Maximum standalone power consumption is 7.7 Watts.

FM