beautypg.com

Tests, Replacement – Despatch LEB Series User Manual

Page 36

background image

28

Tests


Tests should be performed carefully and regularly.
The safety of personnel as well as the condition of
equipment may depend upon the proper operation of
any one of the functions of these controls. Test the
CONTROL instrument every 40 hours. Check that
the CONTROL instrument OUT LED is cycling on and
off. Also, verify that the heater is working.


Test the HI-LIMIT instrument every 40 hours.
With the oven operating at a given
temperature, set the HI-LIMIT down to the
setpoint operating temperature. The HI-LIMIT
instrument has tripped when OP1 is lit. Push

after adjusting the

HI-LIMIT instrument back to a higher setting,
or letting the oven temperature drop a few degrees based on the hysteresis value
of the HI-LIMIT.

Replacement

Parts


To order or return parts, contact the Service
Products Group at Despatch. The Service
Products Group features our Parts Center for
customer service at 1-800-473-7373, option
#2. When returning parts, the Despatch
representative will provide you with an RMA (Return Material Authorization)
number. The RMA number must be attached to the returned part for identification.
When you are ordering parts, be sure to give the model number, serial number and
the part number. This will expedite the process of obtaining a replacement part.

When you have a service need, just contact a product service technician at 1-800-
473-7373
option #3 or FAX 612-781-5485.

WARNINGS:
Failure to heed
warnings in this manual
and on the oven could
result in death, personal
injury or property
damage.

WARNING:
Disconnect the main power switch
or power cord before attempting
any repairs or adjustments.

WARNING:
Disconnect the main power
switch or power cord before
attempting any repair or
adjustment.