Important: Always read and follow operating instructions.

• 25

Pressure Limiter Maintenance

DANGER

Operating a tire changer with a defective,
improperly adjusted, or by-passed pressure
limiter could cause an operator to acciden-
tally over pressurize a tire, resulting in a tire
explosion with severe injury or death to the
operator or bystanders.

Always be sure that the pressure limiter is
present and is operating properly.

DANGER

Never inflate tire above manufacturer’s rec-
ommended pressure after bead is seated.
Pressure limiter is set at 60 PSI. Any required
inflation above 60 PSI should be performed
in an inflation chamber/safety cage or
securely mounted on the vehicle if an infla-
tion chamber is not available. A tire explo-
sion may cause personal injury or death to
operator or bystanders.

The pressure limiter helps prevent inflation of standard

size or larger tires or tubes beyond 60 PSI to minimize

risk of explosion. This device is for the safety of the

operator and bystanders. Proper operation of the pres-

sure limiter is essential to safe operation of the machine.

Check operation of the pressure limiter as shown and

described below at least monthly:

1.

Remove tires and/or wheels from the machine.

2.

Connect the inflation hose to an empty service

tank with a pressure gauge (should read 0). Use a tank

with at least 200 PSI pressure rating.

3.

Depress inflation pedal to position 1 to start airflow

through the hose and into the tank. Maintain a steady

pressure for constant flow.

4.

Watch the rising pressure on the tank gauge and

the gauge on the machine. Machine gauge should

cycle between check and inflation pressures while tank

gauge climbs steadily. As tank pressure reaches 60 PSI,

the pressure limiter should stop the airflow automati-

cally. Both gauges should read 60 PSI ± 5 PSI.

5.

Release inflation pedal. Check manual release

valve function by pressing the button and releasing

pressure from the tank until it reaches 50 PSI. Discon-

nect inflation hose, and release air inside tank.

6.

Replace pressure limiter if it fails to cycle properly

during inflation, if it fails to shut air supply off at 60 PSI,

or if it malfunctions in any other way. Do not operate

machine with a faulty pressure limiter.

IMPORTANT: For models with

“Bead Sealing Only” on the tire

changer, maximum limiter pressure

is 15 PSI (NOT 60 PSI).

Watch

Pressure on

Both Gauges

Air Service

Tank

Tire Changer

Infl ation Hose

Connected to

Tank