Ul9010 ultra-lok, Tool, Optional ½” tool blade change – BAND-IT UL9010 Ultra-Lok Tool User Manual
Page 14
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
Ph: 1-800-525-0758
Fax: 1-800-624-3925
Document # P44987 Rev. N
© Copyright
BAND-IT-IDEX, Inc. 2011
All rights reserved
www.BAND-IT-IDEX.com
Page 14 of 14
UL9010
Ultra-Lok
Tool
Optional ½” Tool
Blade Change
To change out the UL9010 tool to the 1/2” version, the following steps should be followed.
*NOTE: Do not attempt to use 1/2” clamps with 3/4” head. (Adapter change-out: 3-5 minutes)
1. Prior to separation from power drill, back off tension block assembly ½” from head unit. See page 7.
2. Detach tension body from the drill by loosening the single tensioning bolt on the aluminum collar and separating the
two sections.
3. Remove the blade from head by removing two cap screws (M05787) from the top of the head. It is not necessary to
remove entire head from tool in order to remove blade. (Figure 1) Remove the ¾” adapter plate from the blade.
4. Align the ½” adapter plate (M09387) with the blade (M09787) so that the guide is facing up. Incorrect placement will
not allow bands to be inserted into the tool. (Figure 1)
Note: To convert tool back to ¾”, replace ½” insert with ¾” insert (M09887) and follow same instructions.
Be sure to retain unused shear plate for later use.
5. Attach the blade and ½” adapter plate onto head using the two previously removed cap screws. These cap screws
must be tight to assure proper cut-off of clamp tails.
6. Re-attach drill to tension body making sure the drill and tension body are properly aligned, and tighten the single
adapter cap screw located on the aluminum collar.
7. This tool is not designed to work with traditional band and buckle designs.
Must use only BAND-IT Ultra-Lok
clamps.
Figure 1
Figure 2
Optional ½” Insert
(M09387)
Orient as shown
Blade (M09787)
Blade Cap Screw
(M05787) Qty. 2
¼” Ball (M06587)
Bearing Tip (M05387)
Blade (M09787)