beautypg.com

Ul9010 ultra-lok, Tool, Clamp application free-end clamps – BAND-IT UL9010 Ultra-Lok Tool User Manual

Page 10

background image

BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
Ph: 1-800-525-0758
Fax: 1-800-624-3925

Document # P44987 Rev. N

© Copyright

BAND-IT-IDEX, Inc. 2011

All rights reserved

www.BAND-IT-IDEX.com

Page 10 of 14

UL9010

Ultra-Lok

Tool

Clamp Application
Free-End Clamps

Inspect buckle on completed clamp and tap down buckle shroud.









































FRONT VIEW

Completed Free-End Clamp

(Visually inspect lock)

Buckle Shroud

Lock sheared in center
and formed inside
shroud

SIDE VIEW

Completed Free-End

Clamp with buckle

shroud tapped down

as required

Completed clamp
should appear as
shown.

Important: Visually inspect lock formed in band as shown. If lock has slipped under the sheared surface of the
buckle, remove clamp and install a new one at reduced tension by lowering the drill clutch torque setting.

Shear Surface

Section View

Proper clamp

Installation

Section View

Defective Clamp

installation

Lock has slipped back
under sheared buckle
surface