IT6000-AB
3/8” Tie-Lok
®
Tool
1. Begin with Start Menu:\Programs\
Accessories\Communications\HyperTerminal
2. Type a connection name.
3. Click OK
4. “Connect to” dialog box appears
5. In the "Connect Using” text box,
choose COM1, Click OK
6. Properties dialog box appears
7. Port Settings should be:
• Bits per second (2400 or 9600)
• Data bits (8)
• Parity (None)
• Stop bits (1)
• Flow control (NONE)
Click OK
8. Hook up control box, two lines of header
information will appear on the screen:
Program / clamp, etc. Upon connection,
the current clamp information and tool
serial # will appear. Tool is now ready.
9. To capture data- click Transfer, then click
Capture Text, enter a file name and
location, then click Start. *NOTE! *Data
will not be saved unless “stop” is selected
from this same menu.
To check the cut-
off delay timing, hold down the reset button on the breakout box for 3 seconds. You will see “Ready to
check timing” appear on the screen. Activate the tool and it will display the delay duration in decimals of seconds. Hold
down reset button for 3 seconds to return to main menu. See page 33.
(Example of data collection using a Windows XP Operating System)
Tension Cylinder
Pressure Monitoring
System