It6000-ab, Maintenance, 27 of 38 – BAND-IT IT6000-AB 3/8 Tie-Lok Tool User Manual
Page 27: 3/8” tie-lok, Tool
Document # I17796 Rev F
© Copyright
BAND-IT-IDEX, Inc. 2009
All rights reserved
www.BAND-IT-IDEX.com
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street Denver, CO 80216-0307 USA
P: 1-800-525-0758 F: 1-800-624-3925
27 of 38
IT6000-AB
3/8” Tie-Lok
®
Tool
Lubrication
– Follow recommended intervals – Use a synthetic gel lubricant containing
Teflon for the internal parts as shown and described. Lubricate all pivot points and internal
surfaces of maintenance flip cover with a light coating of the lubricant.
Caution
– Excessive amounts of lubricant may result in gripper slippage, requiring a
full repeat of cleaning process.
Tool mechanics
every 25,000 cycles
Lightly lubricate all
points indicated with
red arrows.
Tension Block Assembly
every 12,500 cycles
Note: Ensure no
lubrication is present in
the center of Gripper.
(indicated by the
blue
circle
)
Maintenance Flip Cover
every 12,500 cycles
After the Maintenance
Flip Cover is cleaned,
lubricated, installed and
Quick Release Pins are
in place, apply tension to
the Flip Cover Tightening
Screw and Flip Cover
Head Screws. Refer to
pages 7, 17.
Maintenance