Symptom

Probable cause

Recommended Fix

Page

Control Module air pressure
valve is in "off" position.

Rotate Control Module shut-off valve to open position.
Verify gauges read air pressure and check all air
connections for leaks.

5

Pinched coil hose line

Loosen fitting on coiled hose assembly where it enters
tool body.

6

Kinked or pinched air line

Remove right side handle and inspect air lines.
Remove and replace as required.

28

Tension piston interference
with hanger screw holes.

Loosen Hanger Screw on top of tool. Thread
engagement cannot exceed .125 in.

9

Control Module air pressure
valve is in "off" position.

Rotate Control Module valve to open position. Verify
gauges read air pressure.

5

Clamp tail inside tool

Remove clamp tail, if jammed remove
maintenance/flip cover and remove clamp material.

15-17

Knife is in down position.

Remove or replace knife. Verify missing and or
damaged linkage.

23

Wrong clamp type for tool

Verify proper tool for selected clamp.

Cover page

Handle will not

adjust

Handle nut is
damaged/misaligned.

Remove handle assembly and inspect nut/housing for
damage. Replace as required.

9

Tool will not

operate when

trigger is

depressed

Clamp will not

insert into tool

* = for additional assistance, contact BAND-IT

Troubleshooting