It6000-ab, 33 of 38, 3/8” tie-lok – BAND-IT IT6000-AB 3/8 Tie-Lok Tool User Manual
Page 33: Tool, Tension cylinder pressure monitoring system
Document # I17796 Rev F
© Copyright
BAND-IT-IDEX, Inc. 2009
All rights reserved
www.BAND-IT-IDEX.com
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street Denver, CO 80216-0307 USA
P: 1-800-525-0758 F: 1-800-624-3925
33 of 38
IT6000-AB
3/8” Tie-Lok
®
Tool
Data Capture:
•
The tension feedback system can be used with many data capturing devices including any
computer with Windows operating software.
•
Any properly equipped tool will work with any I75390 data control
box. The tool’s
serial #, clamp count and settings remain with the tool and will be detected by any control box
used. (*the I75390 system will not work with the X75390 system)
•
Any software or hardware that can read the stated format can be used to collect data as it is sent
from the tool.
• Updates or customizations to the program in the control box can be sent to the customer using a
single executable file, no other software is required.
Contact BAND-IT Engineering at 800-525-0758.
Example of Data Output:
Program: I75301 Rev A
Pressure: 55 to 75
Force: 336 to 360
Clamp #
PSI
LBF Tool # Error
30
11111
31
69.1
360 11111
32
64.8
337 11111
33
58.1 302 11111 LOW
34
72.7 378 11111 HIGH
35
69.0
359 11111 C
•
LBF = The calculated force applied to the clamp tail +/- 10 LBF.
•
One or both of the Pressure and Force rows will display, depending on control box settings. See
page XX for instructions on setting the parameters.
•
Clamp number 33 shows a low output and clamp number 34 shows a high output for this example.
•
Clamp number 35 shows the data output when the system fails to detect a complete cutoff cycle in
the time allowed. Note that having the tool on the M28090 device will trigger this error.
•
Clamp number 30 shows output when tool is first connected.
Incompatible tools:
•
In the case that the tool does not have the correct hardware installed the data control box will
output the message “Error! Incompatible tool type detected”
•
Contact BAND-IT for information on upgrades.
Tension Cylinder
Pressure Monitoring
System