It3000-ab, Maintenance, 23 of 28 – BAND-IT IT3000-AB 1/4 Ultra-Lok Tool User Manual
Page 23: 1/4” ultra-lok tool
Document # I17793 Rev D
© Copyright
BAND-IT-IDEX, Inc. 2009
All rights reserved
www.BAND-IT-IDEX.com
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street Denver, CO 80216-0307 USA
P: 1-800-525-0758 F: 1-800-624-3925
23 of 28
IT3000-AB
1/4” Ultra-Lok Tool
A) Remove Cutter Blade as described on page 17.
B) Remove the 2 Knife Pin Access Screws. These
are special length screws.
Important: When repairing tools, threaded fasteners
should be secured using Loctite, Blue - Medium
strength.
To remove Cutter Knife Pin the Knife Assembly
must be in its uppermost position indicated by the
Cutter Knife Pin in line with the access hole. If not
aligned, connect the tool to the Air Controller
Module. Open the Air Shut-off Valve to
momentarily pressurize the tool. Close the valve
and disconnect the tool from the Air Controller
Module. Then push out the Cutter Knife Pin with
a piece of wire (for example, a bent paper clip).
Note the orientation of the knife prior to removal.
Once the pin is removed, grasp the Knife
Assembly with a pair of needle-nose pliers and
pull out of tool head. Examine for wear and
replace if needed.
Re-install all parts in reverse order. After the
Maintenance Flip Cover is installed and Quick
Release Pins are in place, apply tension to the
Flip Cover Screw and Flip Cover Head Screw.
Knife Assembly Replacement:
Maintenance