5.2.2 TCP Server Application: Enable RFC 2217

The underlying protocol of Virtual COM is based on RFC 2217, the Telnet COM Control Option.

Therefore, it is possible to use RFC 2217 with SW550xC in the TCP Server mode. To do so,

refer to

Sec. 5.2.1

to enable Virtual COM, so that SW550xC becomes aware of the commands.

Note that there is no need to configure Virtual COM on the Operating System because Virtual

COM ports would not be used.

5.2.3 TCP Client Application: Enable Virtual COM

It is also possible to run VCOM in TCP Client mode, Figure 5.12. It is usually easier to use

Virtual COM in the Client mode if SW550xC uses dynamic IP (DHCP) because setting a static

IP address in Virt

ual COM’s Control Panel in the Operating System is not possible.

Figure 5.12

 Follow

Sec. 5.1.2

to configure SW550xC in TCP Client mode properly.

 Click on the dropdown box of the Application

option and switch to “Virtual COM” to

enabled Virtual COM application in SW550xC.

Scroll to the bottom of the page and click on “Save & Apply” button to save the