• IRU-6429 Specifications

Detection Range: 1 to 30 ft. (0.3 to 9.1 m)

Outputs: 0-2.5 Vdc or 0-5 Vdc (software selectable)

Operating Voltage: 12-28 Vdc

Programming Voltage: 15-28 Vdc (RST), 12-28 Vdc (RS-232)

Operational Current Draw (without communications): 70 mA @ 24 Vdc

Maximum Power Rating: 2.5 W

Housing: Polycarbonate/PET blend

Mounting: 2 in. NPT (front), 3/4 in. NPT (rear)

Transducer Type: PVDF faced ceramic

Ingress Rating: IP65

Approvals: CSA C/US General Purpose

Sample Rate: 1 to 15 Hz (programmable)

Response Time: Programmable (67 ms minimum)

Resolution: 0.1 in. (2.5 mm)

Accuracy: +/- 0.25% of detected range (with no temperature gradient)

Sensor Adjustments: USB (requires RST-3001) or RS-232 (IRU-6429S only)

Operating Temperature: -40 to 140

0

F (-40 to 60

0

C)

Beam Pattern: 9

0

off-axis (at maximum pulses and sensitivity settings)

Electrical Connection: Pigtail or micro-connector

Frequency: 69 kHz