• IRU 3000 Series Specifications

Detection Range: 1.50 to 50 ft. (0.46 to 15.24 m)

Available Outputs:

4-20 mA

4-20 mA + (2) NPN Trip Points (300 mA max.)

Operating Voltage: 12-28 Vdc

Programming Voltage: 15-28 Vdc

Operational Current Draw (without communications): 70 mA @ 24 Vdc

Maximum Power Rating: 2.5 W

Housing:

IRU-3100 Series: PVC

IRU-3400 Series: Polycarbonate/PET blend

Mounting:

IRU-3100 Series: 3 in. NPT (front), 1 in. NPT (rear)

IRU-3400 Series: 3 in. NPT (front), 3/4 in. NPT (rear)

Transducer Type: PVDF (3400 series) or PVC (3100 series) faced ceramic

Ingress Rating: IP65

Hazardous Location Approvals (CSA C/US):

General Purpose (all models)

Class I, Div. 2, Groups C & D, T6; Ex nA IIB T6, IP65; Class I Zone 2;

AEx nA IIB, T6 (models IRU-3135, IRU-3433, IRU-3435 only)

Sample Rate: 1 to 22 Hz (programmable)

Response Time: Programmable (45 ms minimum)

Resolution: 0.1 in. (2.5 mm)

Accuracy: +/- 0.25% of detected range (with no temperature gradient)

Sensor Adjustments: USB (requires RST-3001)

Operating Temperature: -40 to 140

0

F (-40 to 60

0

C)

Beam Pattern: 9

0

off-axis (at maximum pulses and sensitivity settings)

Electrical Connection: Pigtail or micro-connector

Frequency: 43 kHz