beautypg.com

APG IRU-9400 user manual User Manual

Page 33

background image

Rev. B1, 3/10

IRU Series

33

Automation Products Group, Inc.

APG...Providing tailored solutions for measurement applications

Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]

• IRU-5000 Series Specifications

Detection Range: 4 to 79 in. (102 to 2700 mm)

Available Outputs:

4-20 mA

4-20 mA + (2) NPN Trip Points (300 mA max.)

0-2.5 Vdc or 0-5 Vdc (software selectable)

Operating Voltage: 12-28 Vdc

Programming Voltage: 15-28 Vdc

Operational Current Draw (without communications): 60 mA @ 24 Vdc

Maximum Power Rating: 2.5 W

Housing: Polycarbonate/PET blend

Mounting:

IRU-5410 Series: 1 in. NPT (front), 3/4 in. NPT (rear)

IRU-5420 Series: 2 in. NPT (front), 3/4 in. NPT (rear)

IRU-5320 Series: 2 in. Tri-Clamp

Transducer Type: PVDF faced ceramic

Ingress Rating: IP65

Hazardous Location Approvals (CSA C/US):

General Purpose (all models)

Class I, Div. 2, Groups C & D, T6; Ex nA IIB T6, IP65; Class I Zone 2;

AEx nA IIB, T6 (models IRU-5413, IRU-5415, IRU-5423, IRU-5425 only)

Sample Rate: 1 to 50 Hz (programmable)

Response Time: Programmable (20 ms minimum)

Resolution: 0.1 in. (2.5 mm)

Accuracy: +/- 0.25% of detected range (with no temperature gradient)

Sensor Adjustments: USB (requires RST-3001)

Operating Temperature: -40 to 140

0

F (-40 to 60

0

C)

Beam Pattern: 9

0

off-axis (at maximum pulses and sensitivity settings)

Electrical Connection: Pigtail or micro-connector

Frequency: 143 kHz

This manual is related to the following products: