NOTE: If the internal temperature compensation is enabled and the sensor is

exposed to direct sun light, the radiant heat can warm the sensor housing above

the ambient temperature, which can affect the internal temperature sensor and

cause overcompensation.

Maximum Distance:

Sets the maximum distance, beginning from the

sensor face, to the point where the sensor will stop looking for target signals.

Target signals detected beyond the Maximum Distance value will be ignored by

the sensor. The software distance reading will display the Maximum Distance

value under loss of echo conditions (no targets detected).

View Noise Level

(view only)

:

Displays the number of echoes being

detected by the sensor. Noise levels in excess of 30 are usually an indication of

the presence of a noise source, which may interfere with the sensor operation.

Reducing the sensitivity may help reduce the detected noise level.

Set Noise Threshold:

Sets the threshold level for the noise filter. If the

noise level exceeds this threshold, the sensor will maintain the last reading

before the noise threshold was reached. The reading will be maintained until

the noise level drops below the threshold. Sources of noise are most often from

electric sources but can also be from acoustical sources, such as the release of

high pressure air near the sensor face.