beautypg.com

Solid state relay output, Wiring, Isolated 4-20 ma output – APG IRU-9400 user manual User Manual

Page 12

background image


IRU Series

Rev. B1 3/10

12

Automation Products Group, Inc.

APG...Providing tailored solutions for measurement applications

Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]

Solid State Relay Output

(IRU-2002 only)

Wiring

The IRU series sensors are configured with either a terminal wiring strip (IRU-

2002 & IRU-2003 only), a multiconductor cable or a micro-connector. For

optimal performance, the sensors should be supplied 24 Vdc. A high quality

power supply is recommended.

NOTE: Clock synchronization (available on many models): is used to help

prevent cross-talk between sensors located in close proximity. When the clock

synchronization lines of two or more sensors are connected, the sensors will

synchronize the transmit signals of each sensor. The sensors must share a

common ground in order for the clock synchronization feature to function.

Isolated 4-20 mA Output

(IRU-2003 only)

*Digital Output (IRU-2002 and IRU-2003 only) is used to interface with APG

digital displays--part no. ACC-1007 or ACC-1008.

4-20ma (Output)

Digital Output

4-20ma (Input Power)

+24VDC

Ground

Clock Sync

Relay

Relay

Digital Output

Clock Sync

Ground

+24VDC

This manual is related to the following products: