beautypg.com

Google Message Continuity Setup and Administration Guide User Manual

Page 24

background image

28

Google Message Continuity Setup and Administration Guide

2.

Google Apps information:

Primary domain name: Primary domain registered with Google Apps --
for example,

solarmora.com

. Note: If you have any secondary domains,

be sure to click the Have secondary domains check box.

Consumer Key: OAuth consumer key for the domain -- for example

solarmora.com.

This is usually the same as the Google Apps domain

above, and can be found on the Google Apps control panel > Advanced
Tools > Manage OAuth domain key.

Consumer Secret: OAuth consumer secret for the domain, for example,

Ifsk6eoxguPStT129M+BrGgH+ltRFoiI

IMPORTANT:

Do not save the consumer secret in any temporary

location, to avoid unicode character data loss. Copy and paste the secret
directly from the Google Apps control panel > Advanced Tools > Manage
OAuth domain key.

3.

Sync settings

List of folders to exclude from sync: This is the list of top-level folders
that are excluded from sync.

For example, if you enter “foo” in this field, a top-level folder named “foo”
and all of its sub-folders are excluded. However, if you place a sub-folder
named “foo” in a different top-level folder -- and if it’s a folder that you did
not exclude -- the “foo” sub-folder is also not excluded.

You can specify a comma separated list of folder names in Exchange that
you do not wish to synchronize -- for example, Personal, Friends, Tennis,
etc. By default, Message Continuity does not sync the following folders:
Drafts, Tasks, Outbox, RSSFeeds, and Contacts.

Minimum Delay (sec): Also called sync frequency, Minimum Delay is the
minimum time between two successive syncs. The default is 1800
seconds (30 minutes). By specifying a minimum delay, you can control
the load on your server during the synchronization process. If you want to
speed up synchronization, you can reduce this number.

Number of users to sync in parallel: The default and recommended
value is 10 users. By limiting the number of users to sync in parallel, you
can control the load on your server during the synchronization process.
To speed up synchronization, you can increase this number. However,
increasing the number puts additional load on your server, so we
recommend that you leave this number at 10.

Max message age for uploading new messages: By default, this value
is set at 7 days, so the last 7 days of messages are synchronized (or
migrated) when first running the Continuity Sync Server. Also, the last
7 days of messages are synchronized for a new user when adding that
new user. Maximum value for this setting is 60 days. IMPORTANT: To
migrate messages older than 60 days, use Google Apps Migration for
Microsoft

©

Exchange before you set up Message Continuity. See “Using

GAMME for Migrating Larger Amounts of Mail” on page 9.