SECTION 6 - JLG CONTROL SYSTEM

3121265

– JLG Lift –

6-55

10.

Hit ENTER. The screen should read:

11.

Hit ENTER again to calibrate level sensors.

12.

When calibration has been successful CAL. COM-
PLETE should appear.

13.

Cycle power to the machine.

STEP 3: BLEEDING THE PLATFORM VALVES

1.

Position the Platform/Ground select switch to the
Ground position.

2.

Plug the analyzer into the connector inside the
Ground control box.

3.

Pull out the Emergency Stop switch and start the
engine.