JLG 1100SB Service Manual User Manual
Page 322
![background image](/manuals/551769/322/background.png)
SECTION 6 - JLG CONTROL SYSTEM
6-38
– JLG Lift –
3121265
HI TILTED -
NO/YES
Displays status of hi tilt input. (Displayed if external tilt sensor is
configured)
AUX POWER
OP/CL
Displays the status of the auxiliary power switch input
HORN
OP/CL
Displays the status of the horn input
R FILTER
OP/CL
Displays the status of the return hydraulic filter by-pass switch.
Displayed ONLY if MODEL = 600 (Configuration digit = 3)
C FILTER
OP/CL
Displays measured status of charge pump filter bypass switch.
Displayed ONLY if MODEL = 600 (Configuration digit = 3)
JIB BLOCK
OP/CL
Displays jib block limit switch status. Not displayed if associated
configuration digit = 0
BASKET STOWD
YES/NO
Displays status of basket stowed mode. (Displayed if MODEL
NUMBER = 7 or 8)
SOFT LIMIT
OP/CL
Displays status of soft touch limit switch. Not displayed if associ-
ated configuration digit = 0
SOFT O/R
OP/CL
Displays status of soft touch override switch. Not displayed if
associated configuration digit = 0
GEN SET/WELDER
OP/CL
Displays generator/welder switch input status. Not displayed if
associated configuration digit = 0
LIGHTS
OP/CL
Displays head and tail light switch input status. Not displayed if
associated configuration digit = 0
BSK TILT1
XX.X
Displays indicated platform tilt angle. Displayed on models
equipped with Electronic Platform Leveling.
BSK TILT2
XX.X
Displays indicated platform tilt angle. Displayed on models
equipped with Electronic Platform Leveling.
AXLE RET SW
OP/CL
Displays status of axle extension user switches. (Displayed if
MODEL NUMBER = 7 or 8)
AXLE EXT SW
OP/CL
Displays status of axle retraction user switches. (Displayed if
MODEL NUMBER = 7 or 8)
AXLE LIM SW
RET/EXT
Displays status of axle extension limit switches. (Displayed if
MODEL NUMBER = 7 or 8)
DOS LIM SW
OP/CL
Displays status of Drive Orientation System Limit Switch. (Dis-
played if MODEL NUMBER = 7 or 8)
DOS O/R SW
OP/CL
Displays status of Drive Orientation System Override switch. (Dis-
played if MODEL NUMBER = 7 or 8)
CAPACITY SW
500/1000
Displays status of capacity selection switch. (Displayed if MODEL
NUMBER = 7 or 8)
Table 6-5. Machine Diagnostics Parameters
Diagnostics
Submenu
(Displayed on
Analyzer 1
st
Line)
Parameter (Displayed
on Analyzer 2
nd
Line)
Parameter Value
(Displayed on Analyzer 2
nd
Line)
Description