Machine diagnostics parameters -34 – JLG 1100SB Service Manual User Manual
Page 318

SECTION 6 - JLG CONTROL SYSTEM
6-34
– JLG Lift –
3121265
Table 6-5. Machine Diagnostics Parameters
Diagnostics
Submenu
(Displayed on
Analyzer 1
st
Line)
Parameter (Displayed
on Analyzer 2
nd
Line)
Parameter Value
(Displayed on Analyzer 2
nd
Line)
Description
DRIVE:
DRIVE
FOR/REV XXX%
Displays drive joystick direction & demand
STEER
RIGHT/LEFT XXX%
Displays steer switch direction & demand
4WS
NORMAL/COOR/CRAB
Displays status of four wheel steer input (Displayed if 4WS = 1)
BRAKES
LOCKED/RELEASED
Displays brake control system status
CREEP
ACTIVE/NOT ACTIVE
Displays pump pot creep switch status
CRP MODE
ACTIVE/NOT ACT
Displays creep mode status
QPRX1
ACTIVE/NOT ACTIVE
Displays status of Q-Prox sensor in drive joystick (Displayed if
JOYSTICK TYPE = 1)
QPRX2
ACTIVE/NOT ACTIVE
Displays status of Q-Prox sensor in drive joystick (Displayed if
JOYSTICK TYPE = 1)
TWO SPEED
OP/CL
Displays status of two speed switch input if selected model has
two speed.
2 speed mode
ON/OFF
Displays status of two speed valve if selected model has two
speed
high engine
OP/CL
Displays status of high engine switch
LT F ANG
XX.X
Displays status of left front steer angle (Displayed if MODEL
NUMBER = 7 or 8)
RT F ANG
XX.X
Displays status of right front steer angle (Displayed if MODEL
NUMBER = 7 or 8)
LT R ANG
XX.X
Displays status of left rear steer angle (Displayed if MODEL NUM-
BER = 7 or 8)
RT R ANG
XX.X
Displays status of right rear steer angle (Displayed if MODEL
NUMBER = 7 or 8)
DOS LIM sw
OP/CL
Displays status of Drive Orientation System limit switch. (Dis-
played if MODEL NUMBER = 7 or 8)
DOS O/R sw
OP/CL
Displays status of Drive Orientation Limit System override switch.
(Displayed if MODEL NUMBER = 7 or 8)