MOS90 Fault Finding Flow Charts

Section 3 - Troubleshooting

Page 3-10

067448-003 LX31/LX41 Electric Work Platform

4 Flashes

- Direction contactor welded.

(Point "A" within 6V of B+ve
in neutral)

- Leakage between motor

ar mature and field.

- Drive inhibited.

- Flashes in neutral until

fault is cleared

Check direction contactor tips

Free/change tips

Check power wiring for shorts

Rectify

Check motor for armature to field shorts or

leakage

Rectify

Check for shorts to frame and battery leakage

Rectify

Replace MOS90 Controller

5 Flashes

- Direction contactors (or line

contactor) did not close.

- Motor armature or field

open circuit.

- Point "A" not within 6V of

B+ve within one second of
selecting direction.

- Drive inhibited.

- Flashes until fault is cleared,

when contactor closes.

Check contactor tips

Repair/replace

Check contactor for mechanical operation and

coil O.K.

Repair/replace

Check power and control wiring

Rectify

Check for open circuit motor

Rectify

Replace controller