Section 3 - Troubleshooting

MOS90 Fault Finding Flow Charts

067448-003 LX31/LX41 Electric Work Platform

Page 3-9

3-11 MOS90 F

AULT

F

INDING

F

LOW

C

HARTS

At battery connection, the LED should not illuminate. At key ON, the LED should illuminate steadily. If the
LED illuminates and remains steady, but no drive can be selected, the calibrator can be used to test the
wiring harness.

Check that both directions are not selected.

Check direction switches and wiring. Use

calibrator test mode and check Fwd/Rev/Lift

switch inputs and wiring.

Rectify

Replace MOS90 Controller

3 Flashes

- Point "A" less than 7V in
neutral, or less than 7V for
15mS in drive, or contactor coil
shor t circuit.

- Drive inhibited.

- Recycle to neutral to

clear.

NOTE: If recycling to neutral does not clear the
fault, then the fail-safe is due to a S/C contactor
coil and the keyswitch must be recycled (and the
coil replaced).

Check power and control wiring for shorts

Rectify

Replace Controller

1 Flash

- Power up/Fail-safe Fault

- EEPROM data corrupted on

key

Fault appears at key switch on.

Replace MOS90 Controller

2 Flashes

- Procedure Fault

- Illegal Star tup Sequence.

Two directions selected
together, direction and lift
selected together or lift and
ground selected together

- Drive inhibited

- Flashes until fault is

cleared

Check for correct startup sequence. Was direc-

tion or lift selected at power up?

Retry