PRODUCT
TOTAL PRESSURE GOVERNOR PLUS (TPG+)
BY
AMS
Manual P/N 118711
5.2.28. LAG
∆PSI (Pressure lag)
This menu item allows configuration of the pressure lag which defines the maximum allowable difference that the
actual pressure is behind the commanded set-point before a “wait” (catch-up) state is introduced while operating in
pressure mode.
The display will show
LAG(∆PSI)=X. Use the INC and DEC switches to adjust the pressure lag value.
Range = 1 PSI to 20 PSI (in 1 PSI steps).
[default = 5 PSI]
5.2.29. PUMP
HOURS
This menu item allows the built-in pump-engaged hours counter to be reset to zero or to a desired value (i.e.
replacing a unit).
Pump hours is only incremented when the pump engaged interlock is active.
The display will show
PUMP HOURS. Use the INC and DEC switches to adjust the hours value.
Range = 0.0 hours to 9999.9 hours.
5.2.30. BCM1 VER (Body Control Message 1 version)
This menu item allows configuration of the message configuration version transmitted in the Scania Body Control
Message 1.
The display will show
BCM1 VER: X. Use the INC and DEC switches to adjust the value.
Range = 0 to 255.
[default = 1]
5.2.31. SCANIA MODE? (Scania governor type)
This menu item allows configuration of the Scania requested governor type in the Body Control Message 1.
The display will show
MODE: XXXXXX. Use the INC and DEC switches to adjust the value.
Range = NORMAL or STIFF.
[default = NORMAL]