4. Operation
4.1. Initialization
The TPG+ has a six (6) second power initialization cycle and during this time the display will show:
First second after the power on cycle.
The TPG+ lights all indicators and shows “8.8.8.8. “ in the
pump intake, pump discharge, and RPM display windows.
The Info Center shows “Class 1 TPG-X”. The last letter of
this display indicates the configured control method of the
TPG+.
TPG-C
– CFPG control method
TPG-P
– PGN0 control method
TPG-A
– Analog control method
TPG-S – Scania control method
(See section 6.4 for engine configuration).
Seconds 2 through 4 after the power on cycle.
The TPG+ continues to light all indicators and shows
“8.8.8.8. “ in the pump intake, pump discharge, and RPM
display windows.
The Info Center shows the software version of the TPG+.
The final two seconds after the power on cycle.
The TPG+ turns off all of the indicators and lights only the
decimals of the pump intake, pump discharge, and RPM
display windows.
The Info Center shows “Initializing”.
After the initialization the TPG+ begins normal operation.