5.2.16. IDLE

STEPS

This menu item allows configuration of the analog idle offset voltage, displayed in “counts”. This option is only
available with the Analog Control Type.
Note: This parameter is automatically set by the TPG+ when the Auto Scale routine is run (see section 6.5 for
more information).

The display will show

IdleSteps:XX. Use the INC and DEC switches to adjust to the desired value.

Range = 0 to 60

[default = 32]

5.2.17. IDLE

RPM

This menu item allows configuration of the idle RPM for control via CAN.
The display will show

IDLE RPM, and the set value will be displayed in the RPM window. Use the INC and DEC

switches to adjust the RPM value desired for idle.
Note: Cannot be adjusted below curb idle speed. Option not available for Analog control (see IDLE STEPS).

Range = 650 RPM to 900 RPM (in 5 RPM steps).

[default = 700 RPM]

5.2.18. MAXIMUM

RPM

This menu item allows configuration of the maximum RPM that will be commanded when in PGN0 or SCANia
mode. The display will show

MAXIMUM RPM, and the set value will be displayed in the RPM window. Use the

INC and DEC switches to adjust the maximum RPM value desired.
Note: This value cannot be adjusted above maximum governed speed.

Range = 1900 RPM to 2500 RPM (in 25 RPM steps).

[default = 2400 RPM]

5.2.19. SourceID (CAN message source identification)

This menu item allows configuration of the CAN source message ID number.
The display will show

SourceID=X

. Use the

INC and DEC switches to adjust the CAN source message ID.

Range = 0 – 255.

[default = 7]

5.2.20. PSI TIME-OUT (pressure time out)

This menu item allows configuration of the low pressure time out. When the TPG is governing in pressure mode
and the pressure falls below 30 PSI the TPG will wait the configured number of seconds to attempt to regain
pressure before dropping to IDLE.
The display will show

PSI TIME-OUT. Use the INC and DEC switches to adjust the value desired for the pressure

time out.

Range = 3 seconds to 10 seconds (in 1 second steps).

[default = 5 seconds]

5.2.21. ALLOW PRESET (allow RPM preset use when pressure is detected)

This menu item allows enabling/disabling of throttle mode preset usage when pump pressure over 10 PSI is
detected.
The display will show

ALLOW PRESET. Press the INC or DEC keys to change the display to PRESET RPM=X.

Use the

INC and DEC switches to select Y (yes, enabled) or N (no, disabled).

Range = Y (enabled) or N (disabled).

[default = N]