Technical data sheet – Class1 118711 - TPG+ Governor - 118710 EXTERNAL User Manual

Page 15

background image

FORM-ENG-0018 REV A 05-27-03

PAGE

14

OF 30

TECHNICAL DATA SHEET

DATE

4/9/2009

PRODUCT GROUP

THROTTLE CONTROL

P/N

118710

REV

1.00

607 NW 27th Ave

Ocala, FL 34475

Ph: 352-629-5020 or 1-800-533-3569

Fax : 352-629-2902 or 1-800-520-3473

PRODUCT

TOTAL PRESSURE GOVERNOR PLUS (TPG+)

BY

AMS


Manual P/N 118711

Transmission oil temperature

The info center displays the transmission oil temperature based upon the J1939 CAN message received by the
TPG+. The temperature will be displayed in degrees Fahrenheit (°F) or degrees Celsius (°C) dependent on the unit
of measure configured in the setup menu (see section 5.2.1).

Engine fuel rate

The info center displays the engine fuel rate based upon the J1939 CAN message received by the TPG+. The fuel
rate will be displayed in gallons per hour (G/h) or liters per hour (L/h) dependent on the unit of measure configured
in the setup menu (see section 5.2.1).

Engine hours

The info center displays the engine hours (total hours of operation) based upon the J1939 CAN message received
by the TPG+.

Pump hours

The info center displays the pump hours based upon the amount of time the TPG+ has detected the pump engaged
interlock has been active. The pump hours may be cleared or set to a predetermined number of hours in the setup
menu (see section 5.2.29).

TPG+ alarm status

The info center displays the current alarm status of the TPG+.

The display will show

ALARM OFF when the alarm is not active.

The display will show

ALARM ON when the alarm is active.

The display will show

ALARM SIL=XX when the alarm is active but has been silenced by the user. The

XX will be a value indicating the number of minutes until the alarm will again be allowed to sound (silenced
time remaining).

4.6.2. Silencing

the

alarm

The active alarm can be silenced by pressing and holding the MENU/SILENCE switch for

one second. The info

center display will show

ALARM SIL=10 to indicate that the alarm has been silenced for the standard time of 10

minutes.

Continue holding the MENU/SILENCE switch to increase the silenced time frame to 15 or 20 minutes.

Press and hold the MENU/SILENCE switch for

one second to silence the alarm for the standard time (10

minutes).
Continue holding the MENU/SILENCE switch to increase the alarm silence time (15 or 20 minutes).

The alarm silenced time frame is reset to the standard 10 minutes once all alarm conditions have been
cleared.

The alarm will remain silenced for the selected time frame even if another alarm condition becomes active.