6

Operation

If you attempt to select pressure mode, NO-INTLK will be dis-
played when the MODE switch is pressed and the governor will
revert to RPM mode and RPM will be displayed.

N O - I N T L K

When the PTO Engaged Interlock is active, pressure mode can
be selected and governor operation is identical to RPM mode
except that PSI is displayed instead of RPM and the PRES-
SURE LED will be illuminated.

When the DEC switch is pressed, DECREASE is displayed.

The governor will respond to increase and decrease commands
from the INC and DEC switches within the operating capabilities
of the engine. When the INC switch is pressed, INCREASE is
displayed in the message center.

Each time the INC or DEC switch is released, the current en-
gine RPM is maintained by the governor and the message cen-
ter will display RPM to indicate that the governor is active and
which mode it is operating in.

R P M

I N C R E A S E

D E C R E A S E

R P M

P S I