10

Passwords:
There are several diagnostic modes available in the governor. Access is provided by entering a pass-
word that uses the INC and IDLE switches in a specific sequence.

The Message Center must display [MODE] prior to entering any password.

Governor Self Test:

The Self Test password is:

IDLE INC IDLE INC IDLE INC IDLE INC

This test is capable of determining if there is a problem with the governor that replacement of the gover-
nor display will correct.
Results are displayed in the Message Center as a numeral matching its position in the display.

The Message Center (Test) positions are numbered left to right as follows:

0 1 2 3 4 5 6 7

When the self test starts, the governor checks for the type of output signal present, analog (ANA) or
pulse width modulated (PWM). This is displayed along with the output voltage range if the signal is
analog (Make note of this range. It should vary from ~0.7 to 4.0 VDC). Once this output test is complete
the Message Center will display a results screen. Any X indicates that a particular function has not been
tested.

The Message Center will display X X X 3 - 5 X X for analog or X X X - 4 5 X X for PWM.

Either a ‘3 -’ or a ‘- 4’ are in the 3 and 4 positions dependent on whether the governor is

configured for Analog or PWM output. The 5 in position 5 indicates that the pressure transducer is
transmitting a no pressure signal (expected).
If the pump is engaged, an H (high) will be shown. If the signal is too low, an F (fail) will be displayed.

0

The input to terminal 2 Throttle Ready changed

Release the Park Brake or shift the Transmission to change the interlock

1

The input to terminal 10 Pump Engaged changed

Shift the Pump

2

Each of the switches on the governor have been pressed

The switch pressed will be displayed i-IDLE p-PRESET m-MODE u-INC d-DEC

3

Analog Output, a (-) will be in position 4

4

PWM Output, a (-) will be in position 3

5

Transducer voltage is between 0.3 and 0.9

an (H indicates voltage > 1.0)

(F indicates voltage < 0.3)

6

The High Idle Input (terminal 3) has been toggled

Toggle the High Idle switch ON and then OFF if equipped

7

The internal relay has been activated

NOTE

: T

HIS

CHECK

DOES

NOT

TEST

FOR

THE

VALIDITY

OF

THE

SIGNAL

IN

NOR

IF

THE

SIGNAL

IS

TRULY

SENT

TO

THE

ECM. T

HAT

TEST

MUST

BE

DONE

MANUALLY

IF

IT

IS

THOUGHT

THAT

THE

REMOTE

PTO ON

SIGNAL

THROUGH

THE

GOVERNOR

IS

THE

PROBLEM

.