17

C:\manuals\Uni-Gov-V6-107490

13

Message Center display garbled or dim

This is an internal component of the governor and there is no field repair to correct a dim display. The
governor should be replaced.
Contact Class1 at 1 800 533 3569

14

CAVITATE is displayed in the Message Center

This indicates that the governor has performed a cavitation check and the transducer signal remained
below 25 psi for at least 5 seconds. If the apparatus was run away from water then this is the case. If not,
the

transducer circuit

needs to be checked.

15

PUMP ENGAGED/THROTTLE READY LED’s inoperative

These LED’s are connected directly to their associated interlock. If 12 VDC is present at pin 2, then the
THROTTLE READY LED should be on. If 12 VDC is present at pin 10, then the PUMP ENGAGED LED
should be on.
If 12 VDC is present and the LED is not on, the governor will need to be replaced. The LED’s can be
damaged by electrical “spikes” from the chassis and this condition may or may not be covered by the
Class1 warranty. In any event, this condition is most likely the result of external conditions and they
should be investigated before replacing the governor to prevent a recurrence.