beautypg.com

AEM 30-2340 4-Channel Wideband UEGO AFR Controller User Manual

Page 26

background image



Page 26 10-2340 Rev 05 121012

5 (bit3)

---

---

---

---

---

5 (bit4)

Sensor 8 Heating up

Boolean

0 = false, 1 = true

0

0/1

5 (bit5)

Sensor 6 Heating up

Boolean

0 = false, 1 = true

0

0/1

5 (bit6)

Sensor 4 Heating up

Boolean

0 = false, 1 = true

0

0/1

5 (bit7)

Sensor 2 Heating up

Boolean

0 = false, 1 = true

0

0/1

6

Exhaust Pressure 2

16 bit unsigned

.001 psig/bit

0

0 to 655.35 psig

7

Message ID:

0x000001B3

Source:

AEM 4 Channel UEGO set on MODE 5

Rate:

40ms continuous

Byte

Label

Data Type

Scaling

Offset

Range

0 (bit0)

AFR 9 Ready

Boolean

0 = false, 1 = true

0

0/1

0 (bit1)

AFR 9 Heater Open Error

Boolean

0 = false, 1 = true

0

0/1

0 (bit2)

AFR 9 VM Error

Boolean

0 = false, 1 = true

0

0/1

0 (bit3)

AFR 9 UN Error

Boolean

0 = false, 1 = true

0

0/1

0 (bit4)

AFR 9 IP Error

Boolean

0 = false, 1 = true

0

0/1

0 (bit5)

AFR 9 Heater Time-Out Error

Boolean

0 = false, 1 = true

0

0/1

0 (bit6)

AFR 9 Heater Short Error

Boolean

0 = false, 1 = true

0

0/1

0 (bit7)

AFR 9 Overtemp Error

Boolean

0 = false, 1 = true

0

0/1

1 (bit0)

AFR 10 Ready

Boolean

0 = false, 1 = true

0

0/1

1 (bit1)

AFR 10 Heater Open Error

Boolean

0 = false, 1 = true

0

0/1

1 (bit2)

AFR 10 VM Error

Boolean

0 = false, 1 = true

0

0/1

1 (bit3)

AFR 10 UN Error

Boolean

0 = false, 1 = true

0

0/1

1 (bit4)

AFR 10 IP Error

Boolean

0 = false, 1 = true

0

0/1

1 (bit5)

AFR 10 Heater Time-Out Error

Boolean

0 = false, 1 = true

0

0/1

1 (bit6)

AFR 10 Heater Short Error

Boolean

0 = false, 1 = true

0

0/1

1 (bit7)

AFR 10 Overtemp Error

Boolean

0 = false, 1 = true

0

0/1

2 (bit0)

AFR 11 Ready

Boolean

0 = false, 1 = true

0

0/1

2 (bit1)

AFR 11 Heater Open Error

Boolean

0 = false, 1 = true

0

0/1

2 (bit2)

AFR 11 VM Error

Boolean

0 = false, 1 = true

0

0/1

2 (bit3)

AFR 11 UN Error

Boolean

0 = false, 1 = true

0

0/1

2 (bit4)

AFR 11 IP Error

Boolean

0 = false, 1 = true

0

0/1

2 (bit5)

AFR 11 Heater Time-Out Error

Boolean

0 = false, 1 = true

0

0/1

2 (bit6)

AFR 11 Heater Short Error

Boolean

0 = false, 1 = true

0

0/1

2 (bit7)

AFR 11 Overtemp Error

Boolean

0 = false, 1 = true

0

0/1

3 (bit0)

AFR 12 Ready

Boolean

0 = false, 1 = true

0

0/1

3 (bit1)

AFR 12 Heater Open Error

Boolean

0 = false, 1 = true

0

0/1

3 (bit2)

AFR 12 VM Error

Boolean

0 = false, 1 = true

0

0/1

3 (bit3)

AFR 12 UN Error

Boolean

0 = false, 1 = true

0

0/1

3 (bit4)

AFR 12 IP Error

Boolean

0 = false, 1 = true

0

0/1

3 (bit5)

AFR 12 Heater Time-Out Error

Boolean

0 = false, 1 = true

0

0/1

3 (bit6)

AFR 12 Heater Short Error

Boolean

0 = false, 1 = true

0

0/1

3 (bit7)

AFR 12 Overtemp Error

Boolean

0 = false, 1 = true

0

0/1

4 (bit0)

UEGO Low Voltage Error

Boolean

0 = false, 1 = true

0

0/1

4 (bit1)

EBP sensor ready

Boolean

0 = false, 1 = true

0

0/1