AEM 30-2340 4-Channel Wideband UEGO AFR Controller User Manual
Page 26
Page 26 10-2340 Rev 05 121012
5 (bit3)
---
---
---
---
---
5 (bit4)
Sensor 8 Heating up
Boolean
0 = false, 1 = true
0
0/1
5 (bit5)
Sensor 6 Heating up
Boolean
0 = false, 1 = true
0
0/1
5 (bit6)
Sensor 4 Heating up
Boolean
0 = false, 1 = true
0
0/1
5 (bit7)
Sensor 2 Heating up
Boolean
0 = false, 1 = true
0
0/1
6
Exhaust Pressure 2
16 bit unsigned
.001 psig/bit
0
0 to 655.35 psig
7
Message ID:
0x000001B3
Source:
AEM 4 Channel UEGO set on MODE 5
Rate:
40ms continuous
Byte
Label
Data Type
Scaling
Offset
Range
0 (bit0)
AFR 9 Ready
Boolean
0 = false, 1 = true
0
0/1
0 (bit1)
AFR 9 Heater Open Error
Boolean
0 = false, 1 = true
0
0/1
0 (bit2)
AFR 9 VM Error
Boolean
0 = false, 1 = true
0
0/1
0 (bit3)
AFR 9 UN Error
Boolean
0 = false, 1 = true
0
0/1
0 (bit4)
AFR 9 IP Error
Boolean
0 = false, 1 = true
0
0/1
0 (bit5)
AFR 9 Heater Time-Out Error
Boolean
0 = false, 1 = true
0
0/1
0 (bit6)
AFR 9 Heater Short Error
Boolean
0 = false, 1 = true
0
0/1
0 (bit7)
AFR 9 Overtemp Error
Boolean
0 = false, 1 = true
0
0/1
1 (bit0)
AFR 10 Ready
Boolean
0 = false, 1 = true
0
0/1
1 (bit1)
AFR 10 Heater Open Error
Boolean
0 = false, 1 = true
0
0/1
1 (bit2)
AFR 10 VM Error
Boolean
0 = false, 1 = true
0
0/1
1 (bit3)
AFR 10 UN Error
Boolean
0 = false, 1 = true
0
0/1
1 (bit4)
AFR 10 IP Error
Boolean
0 = false, 1 = true
0
0/1
1 (bit5)
AFR 10 Heater Time-Out Error
Boolean
0 = false, 1 = true
0
0/1
1 (bit6)
AFR 10 Heater Short Error
Boolean
0 = false, 1 = true
0
0/1
1 (bit7)
AFR 10 Overtemp Error
Boolean
0 = false, 1 = true
0
0/1
2 (bit0)
AFR 11 Ready
Boolean
0 = false, 1 = true
0
0/1
2 (bit1)
AFR 11 Heater Open Error
Boolean
0 = false, 1 = true
0
0/1
2 (bit2)
AFR 11 VM Error
Boolean
0 = false, 1 = true
0
0/1
2 (bit3)
AFR 11 UN Error
Boolean
0 = false, 1 = true
0
0/1
2 (bit4)
AFR 11 IP Error
Boolean
0 = false, 1 = true
0
0/1
2 (bit5)
AFR 11 Heater Time-Out Error
Boolean
0 = false, 1 = true
0
0/1
2 (bit6)
AFR 11 Heater Short Error
Boolean
0 = false, 1 = true
0
0/1
2 (bit7)
AFR 11 Overtemp Error
Boolean
0 = false, 1 = true
0
0/1
3 (bit0)
AFR 12 Ready
Boolean
0 = false, 1 = true
0
0/1
3 (bit1)
AFR 12 Heater Open Error
Boolean
0 = false, 1 = true
0
0/1
3 (bit2)
AFR 12 VM Error
Boolean
0 = false, 1 = true
0
0/1
3 (bit3)
AFR 12 UN Error
Boolean
0 = false, 1 = true
0
0/1
3 (bit4)
AFR 12 IP Error
Boolean
0 = false, 1 = true
0
0/1
3 (bit5)
AFR 12 Heater Time-Out Error
Boolean
0 = false, 1 = true
0
0/1
3 (bit6)
AFR 12 Heater Short Error
Boolean
0 = false, 1 = true
0
0/1
3 (bit7)
AFR 12 Overtemp Error
Boolean
0 = false, 1 = true
0
0/1
4 (bit0)
UEGO Low Voltage Error
Boolean
0 = false, 1 = true
0
0/1
4 (bit1)
EBP sensor ready
Boolean
0 = false, 1 = true
0
0/1