AEM 30-2340 4-Channel Wideband UEGO AFR Controller User Manual
Page 25

Page 25 10-2340 Rev 05 121012
Source:
AEM 4 Channel UEGO set on MODE 4
Rate:
40ms continuous
Byte
Label
Data Type
Scaling
Offset
Range
0 (bit0)
AFR 2 Ready
Boolean
0 = false, 1 = true
0
0/1
0 (bit1)
AFR 2 Heater Open Error
Boolean
0 = false, 1 = true
0
0/1
0 (bit2)
AFR 2 VM Error
Boolean
0 = false, 1 = true
0
0/1
0 (bit3)
AFR 2 UN Error
Boolean
0 = false, 1 = true
0
0/1
0 (bit4)
AFR 2 IP Error
Boolean
0 = false, 1 = true
0
0/1
0 (bit5)
AFR 2 Heater Time-Out Error
Boolean
0 = false, 1 = true
0
0/1
0 (bit6)
AFR 2 Heater Short Error
Boolean
0 = false, 1 = true
0
0/1
0 (bit7)
AFR 2 Overtemp Error
Boolean
0 = false, 1 = true
0
0/1
1 (bit0)
AFR 4 Ready
Boolean
0 = false, 1 = true
0
0/1
1 (bit1)
AFR 4 Heater Open Error
Boolean
0 = false, 1 = true
0
0/1
1 (bit2)
AFR 4 VM Error
Boolean
0 = false, 1 = true
0
0/1
1 (bit3)
AFR 4 UN Error
Boolean
0 = false, 1 = true
0
0/1
1 (bit4)
AFR 4 IP Error
Boolean
0 = false, 1 = true
0
0/1
1 (bit5)
AFR 4 Heater Time-Out Error
Boolean
0 = false, 1 = true
0
0/1
1 (bit6)
AFR 4 Heater Short Error
Boolean
0 = false, 1 = true
0
0/1
1 (bit7)
AFR 4 Overtemp Error
Boolean
0 = false, 1 = true
0
0/1
2 (bit0)
AFR 6 Ready
Boolean
0 = false, 1 = true
0
0/1
2 (bit1)
AFR 6 Heater Open Error
Boolean
0 = false, 1 = true
0
0/1
2 (bit2)
AFR 6 VM Error
Boolean
0 = false, 1 = true
0
0/1
2 (bit3)
AFR 6 UN Error
Boolean
0 = false, 1 = true
0
0/1
2 (bit4)
AFR 6 IP Error
Boolean
0 = false, 1 = true
0
0/1
2 (bit5)
AFR 6 Heater Time-Out Error
Boolean
0 = false, 1 = true
0
0/1
2 (bit6)
AFR 6 Heater Short Error
Boolean
0 = false, 1 = true
0
0/1
2 (bit7)
AFR 6 Overtemp Error
Boolean
0 = false, 1 = true
0
0/1
3 (bit0)
AFR 8 Ready
Boolean
0 = false, 1 = true
0
0/1
3 (bit1)
AFR 8 Heater Open Error
Boolean
0 = false, 1 = true
0
0/1
3 (bit2)
AFR 8 VM Error
Boolean
0 = false, 1 = true
0
0/1
3 (bit3)
AFR 8 UN Error
Boolean
0 = false, 1 = true
0
0/1
3 (bit4)
AFR 8 IP Error
Boolean
0 = false, 1 = true
0
0/1
3 (bit5)
AFR 8 Heater Time-Out Error
Boolean
0 = false, 1 = true
0
0/1
3 (bit6)
AFR 8 Heater Short Error
Boolean
0 = false, 1 = true
0
0/1
3 (bit7)
AFR 8 Overtemp Error
Boolean
0 = false, 1 = true
0
0/1
4 (bit0)
UEGO Low Voltage Error
Boolean
0 = false, 1 = true
0
0/1
4 (bit1)
EBP sensor ready
Boolean
0 = false, 1 = true
0
0/1
4 (bit2)
EBP sensor Error Low Volt
Boolean
0 = false, 1 = true
0
0/1
4 (bit3)
EBP sensor detected
Boolean
0 = false, 1 = true
0
0/1
4 (bit4)
CAN Config Mode
Boolean
0 = false, 1 = true
0
0/1
4 (bit5)
CAN Config Mode
Boolean
0 = false, 1 = true
0
0/1
4 (bit6)
CAN Config Mode
Boolean
0 = false, 1 = true
0
0/1
4 (bit7)
CAN Config Mode
Boolean
0 = false, 1 = true
0
0/1
5 (bit0)
---
---
---
---
---
5 (bit1)
---
---
---
---
---
5 (bit2)
---
---
---
---
---