beautypg.com

BNC 835-3 Programmer Manual User Manual

Page 28

background image

Berkeley Nucleonics
www.Berkeley Nucleonics.com

835-3

Programmer’s Manual v1.0

Page 28 of 37

:

FM:DEViation

[SOURce]:FM:SENSitivity
[SOURce]:FM: SENSitivity?
This command sets the frequency modulation deviation. This setting will be used if
:FM:SOURce is set to LFGenerator.
The variable is expressed in units of Hertz.
*RST 10000

:

FM:SENSitivity

[SOURce]:FM:SENSitivity
[SOURce]:FM: SENSitivity?
This command sets the frequency modulation deviation per one volt peak amplitude
signal input. This setting will be used if :FM:SOURce is set to EXTernal.
The variable is expressed in units of Hertz per Volt.
*RST 10000

:

FM:SOURce

[SOURce]:FM:SOURce EXTernal|LFGenerator
[SOURce]:FM:SOURce?
This command selects the FM modulation signal source. If LFGenerator is selected, the
device’s function output has to be connected to the FM/PM input (at the rear panel).
*RST EXT

:

FM:STATe

[SOURce]:FM:STATe ON|OFF|1|0
[SOURce]:FM:STATe?
This command turns the frequency modulation on or off.
*RST OFF

[SOURce]:PM Subsystem (Phase Modulation)

8

Command

Parameters

Unit (default)

[SOURce:]PM:DEViation

1 rad

[SOURce:]PM:SENSitivity

1 rad/V

[SOURce:]PM:SOURce

EXTernal|LFGenerator

EXT

[SOURce:]PM:STATe

ON|OFF|1|0

OFF

:

PM:DEViation

[SOURce]:PM:SENSitivity
[SOURce]:PM: SENSitivity?
This command sets the phase modulation deviation. This setting will be used if
:PM:SOURce is set to LFGenerator.
The variable is expressed in units of radians.
*RST 1

:

PM:SENSitivity

[SOURce]:FM:SENSitivity
[SOURce]:FM: SENSitivity?
This command sets the phase modulation deviation per one volt peak amplitude signal
input. This setting will be used if :PM:SOURce is set to EXTernal.
The variable is expressed in units of radians per Volt.
*RST 1