BNC 835-3 Programmer Manual User Manual
Page 20

Berkeley Nucleonics
www.Berkeley Nucleonics.com
835-3
Programmer’s Manual v1.0
Page 20 of 37
mode, frequency is determined by programmed values for
:LIST:FREQuency.
:FREQuency:STARt
[SOURce]:FREQuency:STARt
[SOURce]:FREQuency:STARt?
This command sets the first frequency point in a step sweep.
*RST The preset value is 1 GHz. Please refer to the Data Sheet.
Range Please refer to the Data Sheet.
:FREQuency:STOP
[SOURce]:FREQuency:STOP
[SOURce]:FREQuency:STOP?
This command sets the last frequency point in a step sweep.
*RST The preset value is 2 GHz.
Range Please refer to the Data Sheet.
[SOURce]:FREQuency:STEP
[SOURce]:FREQuency:STEP[:LINear]
This command sets the step size for a linear step sweep.
[SOURce]:FREQuency:STEP:LOGarithmic
[SOURce]:FREQuency:STEP:LOGarithmic
This command sets the step size for a logarithmic step sweep.
[SOURce]:PHASe Subsystem
Command
Parameters
Unit
(default)
Remark
[SOURce]:PHASe:REFerence
radians
FW2.4
[SOURce]:PHASe[:ADJust]
radians
:PHASe:REFerence
[SOURce]:PHASe:REFerence
This command sets the current output phase as a zero reference. Subsequent phase
adjustments are set relative to the new reference.
:PHASe[:ADJust]
[SOURce]:PHASe[:ADJust]
[SOURce]:PHASe[:ADJust]?
This command adjusts the phase of the signal. The query will only return values in
radians.
*RST The preset value is 0.
[SOURce]:POWer Subsystem
Command
Parameters
Unit
(default)
[SOURce]:POWer[:LEVel][:IMMediate][:AMPLit
ude]
dBm
[SOURce]:POWer:MODE
FIXed|LIST|SWE
FIXed