6.2.10. STAT

Syntax:

STAT CLEAR

STAT?

Form:

Set & Query

Description:

Query equipment information

Parameter:

: TEMP (Temperature in °C)

CLK (Clock source, internal or external)

POW (+6V, -6V, +3.3V, +1.8V, +11V power supply level in V)

TRIG (Trigger feedback for channel 1 to 20. 1 = trigged)

MTRIG (Single shot trigger feedback. 1 = trigged)

RST value:

-

Example:

Clear information: STAT CLEAR

Query temperature: STAT? TEMP (Answer: :STAT TRET,28.30)

Query clock source: STAT? CLK (Answer: :STAT CLK,INTERNAL)

Query power supply level: STAT? POW

(Answer: :STAT POW,6.00,-5.99,3.35,1.75,11.45)

Query trigger feedback: STAT? TRIG

(Answer: :STAT TRIG,1,0,0,1,0,0,0,0,0,0,0,0,0,0,0,1,1,0,0,0)

Query single shot trigger feedback: STAT? MTRIG

(Answer: :STAT MTRIG,0)