6.2.3. TRIGGER
Syntax:
TRIG T
TRIG? T
Form:
Set & Query
Description:
Query trigger mode on channel
Frequency 1 (F1), Frequency 2 (F2), Frequency 3 (F3), Single Shot 1
(SS1), Single Shot 2 (SS2) or Inhibit (INH)
Parameter:
RST value:
INH
Example:
Set channel 2 trigger mode to Frequency 1: TRIG T2,F1
Query trigger mode on channel 2: TRIG? T2 (Answer: :TRIG T2,F1)
6.2.4. VOLTAGE LEVEL
Syntax:
AMPL T
AMPL? T
Form:
Set & Query
Description:
Query voltage level on channel
Parameter:
RST value:
Last value set
Range:
3 000 to 6 000 mV
Example:
Set voltage level to 3.5 V on channel 4: AMPL T4,3500
Query voltage level on channel 4: AMPL? T4 (Answer: :AMPL T4,3500)