6.2.7. FREQUENCIES

Syntax:

FREQ F,

FREQ? F

Form:

Set & Query

Description:

Query frequency of internal Frequency or set frequency of internal

Frequency

Parameter:

: 1, 2 or 3 (Frequency 1, Frequency 2 or Frequency 3)

: Frequency (in Hertz)

RST value:

Last value set

Range:

0.1 to 1 000 Hz (in 1, 2, 5 sequence)

Example:

Set internal Frequency 3 to 0.5 Hz: FREQ F3,0.5

Query frequency of internal Frequency 3: FREQ? F3

(Answer: :FREQ F3,0.5)

6.2.8. RUN

Syntax:

RUN

Form:

Set

Description:

Run a unique single shot sequence (

Same function as the “TRIG”

button on the touch screen

or “Trigger” light/button on web page)

Parameter:

none

RST value:

-

Example:

Run a single shot sequence: RUN