Table i: boiler ratings / data – Burnham V9A User Manual

Page 9

background image

9

Table I: Boiler Ratings / Data

(1)

(2)

(3)

(4)

Boiler

Model

Horse-

Power

Gross

Output

(MBH)

Net I=B=R Rating

Burner Input

Heating

Surface

(Sq. Ft.)

New

Firebox

Volume

(Cu. Ft.)

Pressure

in Firebox

(In. Wtr.

Clmn.)

Water Content

(Gal.)

Boiler Weight

w/Water (Lbs.) Vent

Dia.

(In.)

Sq. Ft.

Steam

MBH

Steam

MBH

Water

Oil

(GPH)

Gas

(MBH) Steam Water

Steam Water Steam Water

V903A

10.3

347

1083

260

302

3.1

447

34.2

37.0

3.2

.33

44.5

66.0

1439

1618

7

V904A

14.4

483

1508

362

420

4.2

606

48.6

54.3

4.8

.38

53.0

75.0

1811

1995

7

V905A

19.3

646

2021

485

562

5.6

808

63.0

71.5

6.4

.31

61.5

84.0

2184

2372

8

V906A

24.1

808

2525

606

703

7.0

1010

77.5

88.8

7.9

.38

70.0

93.0

2557

2749

8

V907A

28.6

959

2996

719

834

8.3

1198

91.9

106.0

9.5

.36

78.5

102.0

2930

3126

8

V908A

33.2

1110

3471

833

965

9.6

1386

106.3

123.3

11.0

.35

87.0

111.0

3303

3503

10

V909A

10.1

1342

4225

1014

1167

11.6

1674

120.7

140.5

12.6

.35

95.5

120.0

3676

3880

10

V910A

45.6

1528

4867

1168

1329

13.2

1905

135.1

157.8

14.2

.40

104.0

129.0

4048

4257

10

V911A

51.2

1714

5513

1323

1490

14.8

2136

149.5

175.0

15.7

.45

112.5

138.0

4421

4634

12

V912A

56.8

1900

6142

1474

1652

16.4

2367

164.0

192.3

17.3

.49

121.0

147.0

4794

5011

12

(1) Type of Build Prefix: K = Knockdown, A = Knockdown w/Assembled Sections, P = Packaged, F = Packaged and Firetested

Trim Suffix: S = Steam Boiler, W = Water Boiler

Fuel Suffix: N = Natural Gas, P = LP Gas, O = Oil, C = Natural Gas/Oil, D = LP Gas/Oil, M - Less Burner

Burner Suffix: B = Beckett, C = Carlin, J = Power Flame JR, P = Power Flame C, W = Webster, L = Less Burner

(2) I=B=R net ratings shown are based on piping and pick-up allowances which vary from 1.333 to 1.289 for steam and 1.15 for water. Consult manufacturer for

installations having unusual piping and pick-up requirements, such as intermittent system operation, extensive piping systems, etc. The burner capacity in

GPH is based on oil having a heat value of 140,000 BTU per gallon.

(3) Firebox volume does not include added volume of 8” extended burner mounting plate (BMP). If 8” BMP is specified (refer to Figure 1), add 0.7 cu. ft. to volume

listed above.

(4) Boiler ratings are based on 12.5% CO

2

(oil) and 9.7% CO

2

(natural gas), + .10” (inches) water column pressure at boiler flue outlet. Ratings shown above apply at

altitudes up to 1000 feet on oil and 2000 feet on gas.
For altitudes above those indicated, the ratings should be reduced at the rate of 4% for each 1000 feet above sea level.

Safety (Relief) Valve Set Pressure: USA Steam Boiler - 15 PSI, USA Water Boiler - 50 PSI

Optional USA Water Boiler - 30 PSI, 80 PSI (special order)

Canadian Steam Boiler - 15 PSI, Canadian Water Boiler - 45 PSI

Optional Canadian Water Boiler - 30 PSI (special order)