beautypg.com

Burnham V9A User Manual

Page 53

background image

53

Boiler

Model

Burner

Input

(GPH)

Burner Mfr.

Burner

Model

Diffuser

Blade

Setting

Damper Settings

Top / Bottom Damper

Pump Pressure (PSI)

Nozzle

Make

Nozzle Data

Low Fire

High Fire

Low Fire High Fire

GPH x

Angle-Type

V904A

4.2

Power Flame

C1-OS

1/8

1/4” / Closed

3/4” / 1/4”

100

270

Delavan

2.50 x 90° - B

V905A

5.6

Power Flame

C1-OS

1/4

Closed / 1/2”

3/8” / 7/8”

100

295

Delavan

3.25 x 80° - B

V906A

7.0

Power Flame

C1-OS

1/4

3/8” / 3/16”

7/8” / 9/16”

100

300

Delavan

4.00 x 80° - B

V907A

8.3

Power Flame

C1-OS

1/2

1/2” / Closed 11/16” / 3/16”

100

275

Delavan

5.00 x 70° - B

V908A

9.6

Power Flame

C2-OAS

1/8

1/2” / Closed

1/2” / 1”

100

260

Delavan

6.00 x 80° - B

V909A

11.6

Power Flame

C2-OAS

1/4

3/8” / 1/16”

3/4” / 5/16”

100

275

Delavan

7.00 x 80° - B

V910A

13.2

Power Flame

C2-OAS

1/4

3/8” / 1/4”

7/8” / 1/2”

100

275

Delavan

8.00 x 80° - B

V911A

14.8

Power Flame

C2-OB

1/4

1/2” / 1/4”

1-1/8” / 5/8”

100

270

Delavan

9.00 x 80° - B

V912A

16.4

Power Flame

C2-OB

1/4

3/4” / 1/4”

1-1/4” / 3/4”

100

270

Delavan 10.00 x 80° - B

Table VI: Power Flame Burner Specifications

OIL BURNERS

GAS BURNERS

Boiler

Model

Burner

Input

(MBH)

Burner Mfr.

Burner

Model

Diffuser No.

(or Diffuser

Blade Setting

Damper Settings

Top / Bottom Damper

Manifold Pressure

“W.C.

** Minimum Inlet

Pressure “W.C.

Low Fire

High Fire

Nat. Gas LP Gas

(1)

Nat.

Gas

LP Gas

(1)

V903A

447

Power Flame JR15A-10

J20611

1/8” / 1/8”

3/8” / 3/8”

3.5

3.5

4.0

4.0

V904A

606

Power Flame JR30A-10

J20610

1/8” / 1/8”

5/8” / 5/8”

3.4

3.4

4.2

4.2

V905A

808

Power Flame JR30A-12

J20615

1/16” / 1/16”

7/16” / 7/16”

3.4

3.4

4.1

4.1

V906A

1010

Power Flame JR30A-12

J20615

1/16” / 1/8”

13/16” / 7/8”

2.1

2.1

4.3

4.3

V907A

1198

Power Flame JR50A-15

J20607

1/4” / 1/4”

1” / 1”

2.3

2.3

5.4

5.4

V908A

1386

Power Flame JR50A-15

J20607

Closed / Closed 1-1/4” / 1-1/4”

2.7

2.7

4.4

4.4

V909A

1674

Power Flame JR50a-15

J20599

5/16” / 1/8”

3/4” / 7/8”

2.4

2.4

5.0

5.0

V910A

1905

Power Flame C2-G-20A

1/4”

3/8” / 1/4”

7/8” / 1/2”

1.8

1.8

5.2

5.2

V911A

2136

Power Flame C2-G-20B

1/4”

1/2” / 1/4”

1-1/8” / 5/8”

2.0

2.0

5.4

5.4

V912A

2367

Power Flame C2-G-20B

1/4”

3/4” / 1/4”

1-1/4” / 3/4”

3.4

3.4

5.0

5.0

* COMBINATION GAS / OIL BURNERS

Boiler

Model

Burner Input

Burner Mfr.

Burner

Model

Diffuser

Blade

Setting

Damper Settings

Top / Bottom Damper

Manifold

Pressure “W.C.

** Minimum Inlet

Pressure - “W.C.

Oil

(GPH)

Gas

(MBH)

Low Fire

High Fire

Low

Fire

High

Fire

Nat.

Gas

LP Gas

(1)

V904A

4.2

606

Power Flame

C1-GO-10

1/8

1/4” / Closed

3/4” / 1/4”

3.6

3.6

4.4

4.4

V905A

5.6

808

Power Flame

C1-GO-10

1/4

Closed / 1/2”

3/8” / 7/8”

3.0

3.0

4.4

4.4

V906A

7.0

1010

Power Flame

C1-GO-12

1/4

3/8” / 3/16”

7/8” / 9/16”

2.6

2.6

4.8

4.8

V907A

8.3

1198

Power Flame

C1-GO-12

1/2

1/2” / Closed 11/16” / 3/16”

2.1

2.1

5.2

5.2

V908A

9.6

1386

Power Flame

C2-GO-15

1/8

1/2” / Closed

1/2” / 1”

2.1

2.1

6.4

6.4

V909A

11.6

1674

Power Flame C2-GO-20A

1/4

3/8” / 1/16”

3/4” / 5/16”

2.3

2.3

4.9

4.9

V910A

13.2

1905

Power Flame C2-GO-20A

1/4

3/8” / 1/4”

7/8” / 1/2”

1.8

1.8

5.2

5.2

V911A

14.8

2136

Power Flame C2-GO-20B

1/4

1/2” / 1/4”

1-1/8” / 5/8”

2.0

2.0

5.4

5.4

V912A

16.4

2367

Power Flame C2-GO-20B

1/4

3/4” / 1/4”

1-1/4” / 3/4”

3.4

3.4

5.0

5.0

*

SEE OIL BURNER DATA ABOVE FOR NOZZLE SIZES AND PUMP PRESSURE SETTINGS.

**

MINIMUM INLET PRESSURE FOR UL GAS TRAINS ONLY. CONSULT FACTORY FOR ADDITIONAL INFORMATION.

NOTES:

(1) Burner not approved in Canada for LP gas.