Emk 46 at z surface-mount magnetic contact, Emk 46 at z surface- mount magnetic contact – Bosch 8-Dec User Manual
Page 286

278 | Detectors and Accessories | Magnetic Contacts Surface Mount
EMK 46 AT Z Surface-
Mount Magnetic Contact
Features
▶ Conventional surface-mount magnetic contact
▶ VdS class B
▶ Head-on or parallel surface mounting
▶ Conventional perimeter protection
Conventional magnet contacts are used for tear-off
surveillance of windows and doors.
Certifications and Approvals
Region
Certification
Europe
CE
EMK 46 AT Z
Germany
VdS
G 191563, B EMK 46
Installation/Configuration Notes
Installation notes
Installation can be head-on or parallel on the door or
window frames.
1
Contact
2
Magnet
3
Installation offset
Surface mounting
•
When used on metal frames, the plastic bases must be
used.
•
The supply lines need to be measured electrically
before connection.
•
The contact and the magnet (6 x 30 mm) can only be
inserted in the surface mounting housing in conjunction
with the plastic sleeve.
•
Installation on ferromagnetic materials is only
permissible with the washer components supplied.
•
Lateral installation offset: max +/- 3 mm.
Distances diagram
Surface mounting with magnet 6 x 30 mm
1
Extraction
2
Proximity switch part
Flush mounting
•
Installation in ferromagnetic materials is not
permissible.
•
Installation can be completed with or without a plastic
sleeve. If no plastic sleeve is used, the components
should be fixed in the bores.
Distances diagram
Head-on installation with magnet 6 x 30 mm
1
Extraction
2
Proximity switch part
Parts Included
Type
Qty.
Component
EMK 46 AT Z
1
Surface-mount magnetic contact
incl. flange, sleeves, and surface-mounting
housing with accessories
Bosch Security Systems B.V.
www.boschsecurity.com
5