Ms-lz flush-mount magnetic contact – Bosch 8-Dec User Manual
Page 270
262 | Detectors and Accessories | Magnetic Contacts Recessed Mount
MS-LZ Flush-Mount
Magnetic Contact
Features
▶ Conventional flush-mount magnetic contact
▶ VdS class B
▶ Head-on or parallel flush mounting
▶ Conventional perimeter protection
Conventional magnetic contacts are used for opening
surveillance of windows and doors.
Certifications and Approvals
Region
Certification
Europe
CE
MS-LZ
Germany
VdS
G 191568, B MS/MSA-LZ
Installation/Configuration Notes
Installation notes
•
Installation can be parallel or head-on.
•
Head-on installation in ferromagnetic materials is
possible with the EG1 flush-mount housing.
•
The magnet should be fixed in the bore.
•
For VdS applications, the MS-LZ flush-mount magnetic
contact cannot be used in ferromagnetic materials.
1
Contact
2
Magnet
Parts Included
Type
Quant. Component
MS-LZ
1
Recessed mount magnetic contacts
incl. 6 m cable
Technical Specifications
Type of installation
Flush, parallel or head-on
Contact
Normally open contact
Permissible contact load
≤ 5 Watt
Switching current
10 to 100 mA
Switching voltage max.
≤ 110 V_
Switch tolerance
≥ 10
7
Magnet
AlNiCo 500
Switch dimensions
Ø 8 mm x 30 mm
Magnet dimensions
Ø 8 mm x 30 mm
Axial installation distance
≤ 15 mm
Temperature range
-25 °C to +70 °C
Connection cable
6 m, LiYY 4 x 0.14 mm
Protection category
IP68
Bosch Security Systems B.V.
www.boschsecurity.com
5