beautypg.com

Emk 46 s z flush-mount magnetic contact – Bosch 8-Dec User Manual

Page 267

background image

Detectors and Accessories | Magnetic Contacts Recessed Mount | 259

EMK 46 S Z Flush-Mount

Magnetic Contact

Features

Conventional flush-mount magnetic contact
VdS class C
Tamper switch
Head-on flush mounting
Conventional perimeter protection

Conventional magnet contacts are used for tear-off
surveillance of windows and doors.

Certifications and Approvals

Region

Certification

Europe

CE

EMK 46 S Z

Germany

VdS

G 196041, C EMK 46 S

Installation/Configuration Notes

Installation notes

Installation is head-on in door or window frames.

Installation can be completed with or without a plastic

sleeve. If no plastic sleeve is used, the components

should be fixed in the bores.

Installation in ferromagnetic materials is not

permissible.

The supply lines need to be measured electrically

before connection.

1

Contact

2

Magnet

3

Installation offset

Distances diagram

1

Extraction

2

Proximity switch part

Note: If the attached magnets are touching each other, there will

be no tamper zone!

Parts Included

Type

Qty.

Component

EMK 46 S Z

1

Built-in magnetic contact

incl. flange and sleeves

Technical Specifications

Type of installation

Flush, head-on

Permissible operating voltage

Max. 40 V_

Contact type

1-pin (normally) open contact

Permissible contact load

6 VA

Max. 100 V_

Max. 500 mA

Protection category

IP 67

VdS environmental class IV

Permissible

ambient temperature

-25 °C to +70 °C

Housing

Material

ABS

Color

White

www.boschsecurity.com

Bosch Security Systems B.V.

5