EMK 46 S Z Flush-Mount
Magnetic Contact
Features
▶ Conventional flush-mount magnetic contact
▶ VdS class C
▶ Tamper switch
▶ Head-on flush mounting
▶ Conventional perimeter protection
Conventional magnet contacts are used for tear-off
surveillance of windows and doors.
Certifications and Approvals
Region
Certification
Europe
CE
EMK 46 S Z
Germany
VdS
G 196041, C EMK 46 S
Installation/Configuration Notes
Installation notes
•
Installation is head-on in door or window frames.
•
Installation can be completed with or without a plastic
sleeve. If no plastic sleeve is used, the components
should be fixed in the bores.
•
Installation in ferromagnetic materials is not
permissible.
•
The supply lines need to be measured electrically
before connection.
1
Contact
2
Magnet
3
Installation offset
Distances diagram
1
Extraction
2
Proximity switch part
Note: If the attached magnets are touching each other, there will
be no tamper zone!
Parts Included
Type
Qty.
Component
EMK 46 S Z
1
Built-in magnetic contact
incl. flange and sleeves
Technical Specifications
Type of installation
Flush, head-on
Permissible operating voltage
Max. 40 V_
Contact type
1-pin (normally) open contact
Permissible contact load
6 VA
Max. 100 V_
Max. 500 mA
Protection category
IP 67
VdS environmental class IV
Permissible
ambient temperature
-25 °C to +70 °C
Housing
•
Material
ABS
•
Color
White
www.boschsecurity.com