Detectors and Accessories | Magnetic Contacts Surface Mount | 283
MSA-LZS Surface-Mount
Magnetic Contact
Features
▶ Conventional surface-mount magnetic contact
▶ VdS class C
▶ Tamper switch
▶ Parallel or head-on surface mounting
▶ Conventional perimeter protection
Conventional magnetic contacts are used for opening
surveillance of windows and doors.
Certifications and Approvals
Region
Certification
Europe
CE
MSA-LZS
Germany
VdS
G 191100, C MS/MSA-LZS
Installation/Configuration Notes
Installation notes
•
Installation can be parallel or head-on.
•
The AG 4 surface mounting housing makes it possible
to install on ferromagnetic materials.
1
Contact
2
Magnet
3
AG4 surface mounting housing
4
Plastic part
5
Offset in the axial direction
6
Warning! The adjustment mark must point to the magnet.
Parts Included
Type
Quant. Component
MSA-LZS
1
Surface-mount magnetic contact with mag-
net incl. 6 m cable and AG4 surface mount-
ing housing with accessories
Technical Specifications
Type of installation
Surface mount, parallel or head-on
Contact
Normally open contact/toggle switch
Permitted contact load
≤ 3 Watt
Switching current
10 A to 100 mA
Switching voltage max.
≤ 30 V_
Switch tolerance
≥ 10
7
Magnet
AlNiCo 500
Switch dimension:
43 x 12 x 12 (mm)
Magnet dimension:
Ø 8 mm x 20 mm
Parallel installation distance:
2 to 6 mm
Temperature range
-25 °C to +70 °C
Connection cable
6 m, LiYY 4 x 0.14 mm
Protection type
IP68
www.boschsecurity.com
Bosch Security Systems B.V.
5