Mk 36 s lsn surface-mount magnetic contact, Mk 36 s lsn surface- mount magnetic contact – Bosch 8-Dec User Manual
Page 357
LSN Peripherals | LSN Magnetic Contacts | 349
MK 36 S LSN Surface-
Mount Magnetic Contact
Features
▶ LSN surface-mount magnetic contact
▶ VdS class C
▶ Tamper switch
▶ Parallel mounting
▶ LSN perimeter protection
Magnetic contacts are used for tear-off surveillance of
doors and windows.
Certifications and Approvals
Region
Certification
Europe
CE
MK 36 S LSN
Germany
VdS
G 101008, C MK 36 S LSN
Installation/Configuration Notes
Installation notes
•
The MK 36 S LSN must be mounted in parallel to the
magnet.
•
The contacts are generally installed in the door or
window frames with the magnet in the window or the
door. If the door or window is opened less than 1 cm,
the magnetic contact should not be able to detect this.
An opening of more than 3 cm must be detected.
•
For installation on ferromagnetic materials, the
distance plates must be used.
1
Contact
2
Magnet
Distances diagram
1
Extraction
2
Proximity switch part
3
Tamper area
4
Secure area
Connecting LSN contacts
•
Each LSN contact is a physical LSN element (1 out of
127 possible per loop).
•
The length of LSN contact connection cables must be
included when planning the total line length of the LSN
loop, as LSN technology is incorporated in these
detectors.
•
Passive coupling elements for joining the connection
cables to the installation cable must be placed as close
as possible to the LSN contacts. The 1 m connection
cable with 2 m LSN cable length is included in the
calculation of the LSN cable length (LSN is carried into
the contacts and back out again).
•
Connector boxes (optional) are classified as installation
material.
Testing LSN contacts
•
Reed switch and microswitch functions can be checked
before installation by a high-Ohm multimeter or
continuity checker (for diode paths).
•
The resistance values are approximate values; a large
change in resistance is significant here.