Ds7445i series led keypads – Bosch 8-Dec User Manual
Page 65
Control Panels, Control Centers, and Keypads | 7000 Line | 57
DS7445i Series LED
Keypads
Features
▶ Easily-accessible instruction label
▶ Three programmable emergency keys
The DS7445i is a four-wire LED keypad that can be used
with the DS7060, DS7080iP-32, DS7200 Series, and
DS7400Xi Series Control Panels. The keypad can be
mounted on a surface or on standard single- or double-gang
boxes, or four-inch square boxes.
The DS7445i has 16 LEDs representing up to eight hard-
wired zones and eight expansion zones. The eight hard-
wired zones on the DS7080iP-32 Control Panel are
represented by the first eight LEDs (the next eight LEDs do
not operate). When using the DS7060 6-Zone Control Panel,
only the first six LEDs operate.
Functions
Easily-accessible Instruction Label
Basic user instructions are located in a pull-out slide that
can be installed to pull from either the left or the right.
Three Programmable Emergency Keys
The three unmarked keys across the bottom row of the
keypad are programmable as a fire emergency key, a special
emergency key, and a panic key. Adhesive labels are
provided for use if the keys are programmed.
Certifications and Approvals
Region
Certification
Europe
CE
1999/5/EC, 2006/95/EC, 2004/108/
EC; EN 55022:2006 + A1:2007, Class B;
EN 50130-4 w/A1:1998 + A2:2003;
EN61000-3-2:2006;
EN61000-3-3:1995; EN 60950-1:2001;
TBR21:1998
Belgium
INCERT
DS7445i: B-509-004/b
Installation/Configuration Notes
Compatibility Information
Control Panel
Number of Operating LEDs on
DS7445V2 Keypad
DS7080iP-32 and DS7400Xi Series
Control Panels
8
DS7060 Control Panel
6
DS7220V2 and DS7240V2 Series
Control Panels
16
Wiring
The wire length between the keypad and the control panel
must be no more than 1000 ft (305 m). Up to two keypads
can be placed along any single 1000 ft (305 m) run of
22 AWG (0.8 mm) non‑shielded, quad (four‑wire) cable.
Three keypads can be used on any single 1000 ft (305 m)
run of 18 AWG (1.2 mm) non‑shielded, quad (four‑wire)
cable.
Note
Do not mount outdoors.
Commercial Fire Applications
The DS7445i can be used in commercial fire applications
with the DS7400Xi Series Control Panels as follows:
•
Single Keypad Use in Commercial Fire Systems: The
keypad must be used on the keypad bus and must be
assigned as keypad address 1. It can be mounted on the
front of the control enclosure. If it is not mounted on
the front of the control enclosure, you must mount it in
the same room as and within 20 ft (6 m) of the control
equipment, and run the wire in conduit or provide
equivalent protection against mechanical damage.
•
Multiple Keypad Use in Commercial Fire Systems: One
keypad must be used on the keypad bus and must be
assigned as keypad address 1. It can be mounted on the
front of the control enclosure. If it is not mounted on
the front of the control enclosure, you must mount it in
the same room as and within 20 ft (6 m) of the control
equipment, and run the wire in conduit or provide
equivalent protection against mechanical damage.
Connect keypads 2 through 10 to the keypad bus and
place as needed within the wiring limits.
Use only one keypad on the option bus and assign it as
keypad address 11, 12, 13, or 14.
Note
Keypad 15 is not available on commercial fire
systems because Option Bus Address 15 is
www.boschsecurity.com